Appendix A: Power Consumption

a
a: P
PPendIx
Power Consumption Management
Purpose
The purpose of the power consumption test is to verify the power dissipation
of system, and the loading of power supply.
Test Equipment
1. 19" LCD Monitor.
2. DC power supply.
3. Operating System OS: Windows 8.1 (32-bit)
4. Burn In Test Ver7.1
5. Intel
®
Thermal Analysis Tool software version: 5.0.1019
6. Direct3D Play Test Program
7. Network test program.
8. USB 2.0 (5V, 0.5A (Cement Resistor)) *4.
Device Under Test
DUT: SYS#1
Test Procedure
1. Make sure mechanical structure and electrical functionality are normal
before testing.
2. Install all I/O load devices and according as system input voltage
specifications to setup DC power supply voltage.
3. Measure system maximum power consumption as below mode:
Standby mode.
BIOS mode.
100% Full loading mode (include USB load fixture)
4. Measure and record system maximum power consumption value.
Copyright © 2016 NEXCOM International Co., Ltd. All Rights Reserved.
C
ower
onsumPtIon
Test Result
System Mode
CPU: Intel
Atom™ CPU E3826 @
®
1.46 GHz
System model: NISE 50 / Revision: B
BIOS: American Megatrends Inc. /
Revision: N050B013 X64
EC Revision: C 00 2
Operating System OS: Windows 8.1
(32-bit)
70
24Vdc
Imax.
Wmax.
Standby mode.
0.10A
2.4W
(S3)
BIOS mode
0.36A
8.64W
100% Full
0.8A
19.2W
loading mode.