Johnson Controls FRICK QUANTUM HD Setup page 71

Compressor control panel communications setup
Hide thumbs Also See for FRICK QUANTUM HD:
Table of Contents

Advertisement

Frick
AB
Modbus
®
Address
Address
Address
4457
N44:57
44458
4467
N44:67
44468
4468
N44:68
44469
4469
N44:69
44470
4470
N44:70
44471
4471
N44:71
44472
4472
N44:72
44473
4473
N44:73
44474
4474
N44:74
44475
4483
N44:83
44484
4484
N44:84
44485
4485
N44:85
44486
4486
N44:86
44487
4487
N44:87
44488
4488
N44:88
44489
4489
N44:89
44490
4490
N44:90
44491
4491
N44:91
44492
4492
N44:92
44493
4493
N44:93
44494
4494
N44:94
44495
4495
N44:95
44496
4496
N44:96
44497
4497
N44:97
44498
4498
N44:98
44499
4507
N45:07
44508
4517
N45:17
44518
4518
N45:18
44519
4519
N45:19
44520
4520
N45:20
44521
4521
N45:21
44522
4522
N45:22
44523
4523
N45:23
44524
4524
N45:24
44525
4533
N45:33
44534
QUANTUM™ HD COMPRESSOR CONTROL PANEL
COMMUNICATIONS SETUP
MODE VALUES: (Continued)
Read/
Description of Data
Write
R
Sequencing Enable - System 2
R
Sequencing – Sys. 2 Comp 1 Comp Status
R
Sequencing – Sys. 2 Comp 2 Comp Status
R
Sequencing – Sys. 2 Comp 3 Comp Status
R
Sequencing – Sys. 2 Comp 4 Comp Status
R
Sequencing – Sys. 2 Comp 5 Comp Status
R
Sequencing – Sys. 2 Comp 6 Comp Status
R
Sequencing – Sys. 2 Comp 7 Comp Status
R
Sequencing - Sys 2 Comp 8 Comp Status
R
Sequencing – Sys. 3 Comp 1 Comp Mode
R
Sequencing – Sys. 3 Comp 2 Comp Mode
R
Sequencing – Sys. 3 Comp 3 Comp Mode
R
Sequencing – Sys. 3 Comp 4 Comp Mode
R
Sequencing – Sys. 3 Comp 5 Comp Mode
R
Sequencing – Sys. 3 Comp 6 Comp Mode
R
Sequencing – Sys. 3 Comp 7 Comp Mode
R
Sequencing – Sys. 3 Comp 8 Comp Mode
R
Sequencing – Sys. 3 Comp 1 Capacity Mode
R
Sequencing – Sys. 3 Comp 2 Capacity Mode
R
Sequencing – Sys. 3 Comp 3 Capacity Mode
R
Sequencing – Sys. 3 Comp 4 Capacity Mode
R
Sequencing – Sys. 3 Comp 5 Capacity Mode
R
Sequencing – Sys. 3 Comp 6 Capacity Mode
R
Sequencing – Sys. 3 Comp 7 Capacity Mode
R
Sequencing – Sys. 3 Comp 8 Capacity Mode
R
Sequencing Enable - System 3
R
Sequencing – Sys. 3 Comp 1 Comp Status
R
Sequencing – Sys. 3 Comp 2 Comp Status
R
Sequencing – Sys. 3 Comp 3 Comp Status
R
Sequencing – Sys. 3 Comp 4 Comp Status
R
Sequencing – Sys. 3 Comp 5 Comp Status
R
Sequencing – Sys. 3 Comp 6 Comp Status
R
Sequencing – Sys. 3 Comp 7 Comp Status
R
Sequencing – Sys. 3 Comp 8 Comp Status
R
Oil Pump Mode
090.040-CS (JAN 14)
Value Code
0 = Disabled
1 = Enabled
0 = Off
1 = Running
20 = Starting
30 = Stopping
31 = Stopping - High Capacity
32 = Stopping - Pumpdown
0 = Manual
1 = Automatic
2 = Remote - Communications
3 = Remote - IO
5 = Remote – Sequencing
0 = Manual
1 = Automatic
2 = Remote - Communications
3 = Remote - IO
4 = Remote - 4-20 Input
5 = Remote – Sequencing
0 = Disabled
1 = Enabled
0 = Off
1 = Running
20 = Starting
30 = Stopping
31 = Stopping - High Capacity
32 = Stopping - Pumpdown
0 = Manual
1 = Automatic
Page 71

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FRICK QUANTUM HD and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents