Step: Changing The Transmission Rate At The Mpi/Dp Interface - Siemens SIMATIC S7-300 Getting Started

Automation systems cpu 317t-2 dp: controlling a sinamics s120
Hide thumbs Also See for SIMATIC S7-300:
Table of Contents

Advertisement

Learning units

3.4 3. Step: Changing the transmission rate at the MPI/DP interface

Step
Activity
8
Confirm the default settings of the PROFIBUS configuration with
"OK".
9
Add a digital input module and a digital output module.
You now have this layout:
3.4
3. Step: Changing the transmission rate at the MPI/DP interface
Procedure
Step
Activity
1
In the mounting rail, double-click "MPI/DP" to open the
MPI/DP interface (X1) in the HW Config.
2
Click the "Properties" button.
3
Click MPI(1) and then click "Properties".
4
Select the "Network settings" tab and select a transmission
speed of "1.5 Mbps".
16
Result
Result
The "Properties - MPI/DP" dialog box opens.
The "Properties – MPI interface MPI/DP"
dialog box opens.
The "Properties - MPI" dialog box opens.
CPU 317T-2 DP: Controlling a SINAMICS S120