3.12

11. Step: Creating the technology DBs

Procedure
Sequence
Activity
1
Change to "Technological Objects Management". Confirm the first message box with "OK", and the second
with "Yes".
If you are not running the "Technological Objects Management" application yet, you can open it by double-
clicking "Technological Objects" in the "Technology" folder in SIMATIC Manager (see also step:
"Configuring the axes with S7T Config").
Result: The "Technological Objects Management" opens.
Edit the DB numbers as shown in the figure in order to adapt these for use in our example.
2
Create the technology DBs listed below by clicking "Create":
Axis_1
Axis_2 (if this exists)
Trace
MCDevice
3
Close the "Technological Objects Management" via the
Technological objects > Exit menu command.
CPU 317T-2 DP: Controlling a SINAMICS S120
Getting Started, 03/2008, A5E00480391-03
3.12 11. Step: Creating the technology DBs
Result
The system generates the technology data
blocks DB1, DB2, DB3 or DB4.