Manual Mode
Engaging the Fixture
1
Figure 32 Vacuum fixture
2
3
4
5
6
7
8
Medalist i1000 Installation Guide
Place the fixture between the guide rails and push it over the tester
interface.
Press the MANUAL button to initiate manual mode.
Press FIXTURE LOCK to lock the fixture.
Press MODUAL UP/DN to raise the module support.
Press MODUAL RELEASE to move the module holder to the unlocked
position (see
Figure 34
Press MODUAL UP/DN to lower the module onto the tester interface.
(Note that the light turns off when the module is lowered.)
Press and hold the MOTOR LINK button until the fixture is engaged.
There is no indicator to signal if the module is fully engaged. Typically
it will be fully engaged in about 6 seconds.
Press MODUAL RELEASE to return the module holder to its locked
position (see
Figure 34
on page 27).
on page 27).