Powtran PI9100 Series Manual page 77

Table of Contents

Advertisement

Chapter 5 Function parameter
No. Code
Parameter name
387.
E2.02 PID feedback source
388.
E2.03 PID action direction
389.
PID setting feedback
E2.04
range
390.
PID inversion cutoff
E2.05
frequency
391.
E2.06 PID deviation limit
392.
PID differential
E2.07
limiting
393.
PID reference change
E2.08
time
394.
PID feedback filter
E2.09
time
395.
E2.10 PID output filter time 0.00s to 60.00s
396.
PID feedback loss
E2.11
detection value
397.
PID feedback loss
E2.12
detection time
398.
Proportional gain
E2.13
KP1
399.
E2.14 Integration time Ti1
400.
E2.15 Differential time Td1 0.00s to 10.000s
401.
E2.16 Proportional gain
KP2
402.
E2.17 Integration time Ti2
403.
E2.18 Differential time Td2 0.00 to 10.000
Setting range
0 to 8
0: positive
1: negative
0 to 65535
0.00 to
F0.19(maximum
frequency)
0.0% to 100.0%
0.00% to 100.00%
0.00s to 650.00s
0.00s to 60.00s
0.0%: not judged
feedback loss
0.1% to 100.0%
0.0s to 20.0s
0.0 to 200.0
0.01s to 10.00s
0.0 to 200.0
0.01s to 10.00s
72
Factory
Change Reference
setting
0
0
1000
0.00Hz
0%
0.10%
0.00s
0.00s
0.00s
0.0%
0.0s
80.0
0.50s
0.000s
20.0
2.00s
0.000s