16
Reserve
Frequency source
17
main set
Maximum output
F2.09
frequency of high-speed
pulse
SPB terminal is selected as pulse output, the function code is used to select the
maximum value of output pulse.
SPB switching quantity
F2.10
output delay time
F2.11
Relay 1 output delay time
Expansion DO output
F2.12
delay time
F2.13
SPA output delay time
F2.14
Relay 2 output delay time
Set the delay time from occurrence to Actual output for output terminal SPA, SPB, relay
1, relay 2 and expansion DO.
F2.15 DO output terminal
active status selection
To define the output logic for output terminal SPA, SPB, relay 1, relay 2 and expansion
DO .0: positive logic:It is active status when the digital output terminal is connected with
the corresponding common terminal, inactive when disconnected; 1: anti-logic:It is inactive
0~max output frequency
0.01kHz to 100.00kHz
0.0s to 3600.0s
0.0s to 3600.0s
0.0s to 3600.0s
0.0s to 3600.0s
0.0s to 3600.0s
SPB switching
quantity active
Units digit
status selection
Positive logic
Anti-logic
Relay 1 terminal
active status
Tens digit
setting (0 to 1,
as above)
Expansion D0
terminal active
Hundreds
status setting (0
digit
to 1, as above)
SPA terminal
active status
Thousands
setting (0 to 1,
digit
as above)
Relay 2 terminal
Ten
active status
thousands
setting (0 to 1,
digit
as above)
115
Chapter 5 Function parameter
50.00kHz
0.0s
0.0s
0.0s
0.0s
0.0s
0
1
00000