Powtran PI9100 Series Manual page 225

Table of Contents

Advertisement

Chapter 10 Options
10-14.Specifications of circuit breakers, cables and contactors
Circuit
Model
breaker(A)
R40G2
10A
R75G2
16A
1R5G2
20A
2R2G2
32A
004G2
40A
5R5G2
63A
7R5G2
100A
011G2
125A
015G2
160A
018G2
160A
022G2
200A
030G2
200A
037G2
250A
045G2
250A
055G2
315A
R75G3
10A
1R5G3
16A
2R2G3
16A
004G3
25A
5R5G3
25A
7R5G3
40A
011G3
63A
015G3
63A
018G3
100A
022G3
100A
030G3
125A
037G3
160A
Input
line/output line
Rated operational current A of contactor
(Copper cable)
mm2
1.5
2.5
2.5
4
6
6
10
10
25
25
25
35
35
70
70
1.5
1.5
2.5
2.5
4
4
6
6
10
10
16
25
220
(voltage 380V or 220V)
10
10
16
20
25
32
63
95
120
120
170
170
170
230
280
10
10
10
16
16
25
32
50
63
80
95
120

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents