Chapter 5 Function parameter
AI1 input filter time is used to set AI1 software filter time, When the on-site analog
quantity is easily interfered, please increase the filter time to stabilize the detected analog
quantity, but the greater filter time, the slower analog detection response, the proper setting
method depends on the actual application.
In the different applications, the 100.0% of analog setting vary from the meaning of its
corresponding nominal value, please refer to the description of each application for details.
The two legends are for two typical settings.
Corresponding setup
(Frequency,torque)
Corresponding setup
(Frequency, torque)
Minimum input value
F1.16
for AI curve 2
Minimum input
F1.17
setting for AI curve 2
Maximum input for AI
F1.18
curve 2
Maximum input
F1.19
setting for AI curve 2
For the function and use of curve 2, please refer to the description of curve 1.
100%
0V(0mA)
100%
0V(0mA)
-100%
Relationship between analog reference and set amount
0.00V to F1.18
-100.00% to 100.0%
F1.16 to 10.00V
-100.00% to 100.0%
10V(20mA)
10V(20mA)
106
A1
A1
0.00V
0.0%
10.00V
100.0%