No. Code
Parameter name
Torque control
305.
FA.05
forward maximum
frequency
Torque control
306.
FA.06
backward maximum
frequency
307.
FA.07 Torque filter time
5-1-13.Fb Group - Control optimization parameters
No. Code
Parameter name
308.
Fast current limiting
Fb.00
manner
309.
Fb.01 Undervoltage point
setting
310.
Fb.02 Overvoltage point
setting
Deadband
311.
Fb.03
compensation mode
selection
312.
Fb.04 Current detection
compensation
Vector optimization
313.
Fb.05
without PG mode
selection
Upper limiting
314.
Fb.06
frequency for
DPWM switching
315.
PWM modulation
Fb.07
manner
Setting range
0.00Hz to
F0.19(maximum
frequency)
0.00Hz to F0.19
(maximum
frequency)
0.00s to 10.00s
Setting range
0: disable
1: enable
50.0% to 140.0%
200.0V to 2500.0V
0: no compensation
1: compensation
mode 1
2: compensation
mode 2
0 to 100
0: no optimization
1: optimization
mode 1
2: optimization
mode 2
0.00Hz to 15.00Hz
0: asynchronous
1: synchronou
65
Chapter 5 Function parameter
Factory
Change Reference
setting
50.00Hz
50.00Hz
0.00s
Factory
Change Reference
setting
1
100.0%
-
1
5
1
12 .00Hz
0
page
151
151
151
page
151
152
152
152
152
153
153
153

Hide quick links: