3.5 Setting Stow and Unstow

This section describes how to set the stow and unstow presets.

3.5.1.1 With the GUI

With the GUI
1. Pan and tilt the positioner until it reaches the desired position.
2. Set Preset 1 (Preset 1 is the always the stow position)
3. Set preset 2 (Preset 2 is always the unstow position)

3.5.1.2 With a Push Button Controller

With a push button controller:
1. Pan and tilt the positioner until it reaches the desired position.
2. Press and hold the left and right pan buttons simultaneously.
3. With the left and right pan buttons pressed, select "Stow" to set the stow preset
position, or "Unstow" to set the unstow preset position.

3.5.1.3 With a Toggle Switch Controller

With a toggle switch controller:
If using a controller with toggle switches, a jumper will need to be used to connect the
clockwise and counterclockwise contact closure wires to the contact closure power wire.
1. Pan and tilt the positioner until it reaches the desired position.
2. Attach a jumper from both the white (counterclockwise) contact closure wire and
green (clockwise) contact closure wire to the red (power) contact closure wire.
3. Select "Stow" to set the stow preset position, or "Unstow" to set the unstow preset
position.
IMPORTANT: It is essential that Stow/ Unstow positions are set, before assigning
any new limit stops
PM-01010-REV 2