3.4.3.5 Setting Limit Stops with the Keyboard

To set the electronic limit stops with the keyboard:
1. Drive the positioner to the desired electronic limit stop.
2. Press [Set].
3. Press [N] where "N" represents the number which corresponds to the preset being
adjusted. Reference Table 3-2 to determine which number to use to change each
electronic limit stop.
Set Preset [N]
80
81
82
83
4. Press [Pre]. The electronic limit has been adjusted and the positioner will no longer
move past that point.
5. Test to ensure electronic limit stop has been properly set.
Note that it is possible to set the electronic limit stops such that the positioner cannot move
(e.g; setting the clockwise and counterclockwise limits to the same spot). If this happens,
clear the electronic limit stops and reset electronic limit stops to the desired location.

3.4.3.6 Clear Limit Stops with the Keyboard

To clear the electronic limit stops with the keyboard:
1. Press [Set].
2. Press [N] where "N" represents the number which corresponds to the preset being
cleared. Reference Table 3-3 to determine which number to use to change each
electronic limit stop.
3. Press [Pre]. The electronic limit stops have been cleared.
Ensure new limit stop is set.
3-46
Table 3-2 Limit Stop Presets
Function
Stores New Pan Left (Counterclockwise) Limit
Stores New Pan Right (Clockwise) Limit
Stores New Up Limit
Stores New Down Limit