4.10 Data points

● Data type alias
Data type in the transferred user data (DATAPOINT_TYPE)
● Station
Assigned station
● Topic
Assigned topic
You assign the respective data point to a topic here (single assignment). See above for
the procedure.
4.10
Data points
4.10.1

Transmission time and transferred data

Note
Requirements for the transfer (Cloud)
The following conditions must be met to transfer a value:
• The data point is assigned to a topic in the configuration.
• At least one trigger condition is met.
Time of the data transfer and quantity of the transmitted data
Triggering the data transfer is different for the two target systems:
● Cloud
The transfer time is controlled via trigger, refer to the section Data points (Page 101).
You specify the time when the values of data points are transferred to the broker for each
data point with the "Trigger".