Syslog messages
C.2 Syslog messages
C.2.5
Remote session termination
SE_RAS_SESSION_TERMINATED_INACTIVITY_(protocol)
Message text
Example
Explanation
Severity
Facility
Standard
C.2.6
Concurrent session control
SE_ACCESS_DENIED_NUMBER_OF_CONCURRENT_SESS_(protocol)
Message text
Example
Explanation
Severity
Facility
Standard
C.2.7
Non-repudiation (config change)
SE_CONFIG_CHANGE_(protocol)_(complete configuration)
Message text
Example
Explanation
Severity
Facility
Standard
SE_CONFIG_CHANGE_(protocol)_(reset to factory)
Message text
Example
Explanation
Severity
Facility
Standard
146
{Protocol}: Remote session {Config detail} was closed after {Time second} seconds of inactivity.
WBM: Remote session o1cs3jjKy... was closed after 600 seconds of inactivity.
The session was closed after a period of inactivity.
Notice
local0
IEC 62443-3-3 Reference: SR 2.6
{Protocol}: The maximum number of {Max sessions} concurrent login session exceeded.
WBM: The maximum number of 1 concurrent login sessions exceeded.
The maximum number of simultaneous sessions has been reached.
Warning
local0
IEC 62443-3-3 Reference: SR 2.7
{Protocol}: User {User name} has changed configuration.
WBM: User admin has changed configuration.
User has changed the configuration data by loading a new *.cfg file.
Info
local0
IEC 62443-3-3 Reference: SR 2.12
{Protocol}: User {User name} has initiated a reset to factory defaults.
WBM: User admin has initiated a reset to factory defaults.
User has initiated a reset to factory settings.
Info
local0
IEC 62443-3-3 Reference: SR 2.12
Operating Instructions, 10/2019, C79000-G8976-C503-02