SERVICE PROCEDURE

CHECK FOR LOOSE ROPSCAB MOUNT BOLTS

Check that there are no loose or damaged bolts.
METHOD OF TIGHTENING MOUNT BOLT
1. First, tighten bolts (1) - (21) to a tightening torque of 294 ± 29.4 Nm. The order for tightening is as shown in the
diagram.
2. Tighten bolts (22) and (23) to a tightening torque of 279 ± 27.9 Nm in the order shown by the direction of the
arrow.
3. Use an impact wrench or ordinary wrench to tighten bolts (1) - (21) a further 60°.