General visual inspection
The daily routine should comprise a visual inspection around the entire paver finisher.
The following items must be checked:
- Are components or controls damaged?
- Are there leaks on the engine, the hydraulics, the gearbox, etc.?
- Are all fastening points (conveyor, auger, screed, etc.) in order?
- Are the warnings affixed to the vehicle complete and legible?
- Are the non-slip surfaces at ladders, steps, etc. in correct condition, not worn
or soiled?
m
Immediately take actions to correct any detected malfunction to avoid damages, dan-
gers or environmental hazards!
3
Check that the bolts and nuts fit firmly
NOTE
Bolts and nuts must be checked regularly to ensure that they fit firmly; retighten them
if necessary.
The spare parts catalogue states the special torques at the corresponding parts.
A
For the necessary standard torques, please refer to the section "Bolts - torques"
A
Caution! Possible damage to or destruction of parts!
- Self-locking nuts must always be replaced after removal.
- Special torques not mentioned in this manual are stated
at the corresponding place in the spare parts catalogue.
- Screws locked with screw cement must be cemented in
again if found to have come loose.
Always use the stated torque.
- Stated torques for screwed connections apply
to dry (unoiled) state
- Do no reuse screws inserted with the maximum permit-
ted torque; instead, replace with new screws.
- Screws in strength class 12.9 should only
be used once.
- All screwed connections must be clean.
- Check all reused components of the screwed connection
for any signs of damage.