Fayat Group DYNAPAC SD2500W Operation & Maintenance Manual page 479

Paver finisher
Hide thumbs Also See for DYNAPAC SD2500W:
Table of Contents

Advertisement

Crankshaft ventilation filter (7)
Change filter element
- Take the cover off (A) and remove the
filter cover (B)
- Remove the depleted filter.
Check the cover and cover seal for any
A
signs of damage and replace if neces-
sary!
- Clean the contact surface (D) of the fil-
ter and the sealing surfaces of the
O-rings with a cloth and light solvent
and then dry them with a clean cloth.
- Clean the filter cover with warm soapy
water (E) and dry it with compressed
air.
f
Wear protective goggles when using
working with compressed air! Never
blow compressed air towards other peo-
ple!
f
Use personal safety equipment when
cleaning with solvents! Avoid contact
with skin!
- Apply a little fresh engine oil to the O-
rings (F) of the new filter and set the fil-
ter correctly on its contact surface.
- Fit the cover (B):
- Start with the inside screw (G) and
work forwards clockwise.
m
The torque for the cover screws is 7 Nm.
m
After installation, check correct sealing
during a trial run.
B
C
F
D
G
A
E
F 53 17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dynapac sd2500ws897898

Table of Contents