When equipped with an electric screed, it is possible for the lamps to flicker irregularly
A
during the heating-up phase with simultaneous operation of 500 watt spotlights (o)
and the illuminated balloon (o).
Preferably only one type of lighting should be used during the heating-up phase.
Maintenance
Occasionally clean or replace the air
m
filter (9) beneath the connection plate.
m
Do not use solvents to clean the balloon
skin!
Replacing the lamp
- Disconnect the power cable and open
the zip fastener of the skin.
f
Let lamp cool down completely!
m
Always wear the supplied cotton glove to touch the lamp!
- Press the lamp down gently to remove it.
- Insert the new lamp in the socket.
- Close the zip fastener of the balloon skin.
D 31 42