ID
Display on LCD Keypad
176
Action condition
Action time
Fault treatment parameter
Reset method
Reset condition
Record
Cause
Encoder's rotating turns exceeds
the countable range
Chapter 14 Fault Codes and DescriptionsC2000 Plus
Fault Name
Encoder multi-turn
When the multi-turn counting exceeds the encoder's
overflows
maximum counting value (the encoder rotates over the
(EcOF)
countable maximum turns), the EcOF occurs.
Action and Reset
Encoder rotates for turns over its counting upper limit
Act immediately
Pr.10-60: bit8–11
0: Warn but continue operation
1: Warn and stop
2: No warn and no stop
Manual reset
Press RESET key to clear the fault
Yes
1. Press RESET key to clear the fault
2. Reboot the drive.
3. Re-execute the homing process
14-103
Fault Descriptions
Corrective Actions