Parallel Connection Control
Application Manual
Applicable Products:
C2000 Plus / C2000-HS / C2000-R

Advertisement

loading
Need help?

Need help?

Do you have a question about the C2000 Plus and is the answer not in the manual?

Questions and answers

Summary of Contents for Delta C2000 Plus

  • Page 1 Parallel Connection Control Application Manual Applicable Products: C2000 Plus / C2000-HS / C2000-R...
  • Page 2 All information contained in this user manual is the exclusive property of Delta Electronics Inc. (hereinafter referred to as "Delta ") and is protected by copyright law and all other laws. Delta retains the exclusive rights of this user manual in accordance with the copyright law and all other laws. No parts in this manual may be reproduced, transmitted, transcribed, translated, or used in any other ways without the prior consent of Delta.
  • Page 3 (Translation of the original instructions)
  • Page 4 PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.  Disconnect AC input power before connecting any wiring to the AC motor drive.  When wiring, turn off the AC motor drive power first. It takes a certain time for the internal DC capacitor to discharge. A charge may still remain in the DC link capacitors with hazardous voltages before the POWER LED is OFF.
  • Page 5  The performance of electrolytic capacitor will degrade if it is not charged for a long time. It is recommended to charge the drive which is stored in no charge condition every 2 years for 3–4 hours to restore the performance of electrolytic capacitor in the motor drive.
  • Page 6: Table Of Contents

    Table of Contents System Architecture Overview ........................ 1 1-1 Overview of Parallel Control ..........................2 1-2 Model List ................................3 1-3 Accessories Overview ............................7 Wiring ............................... 15 2-1 System Wiring Diagram ............................ 17 Parallel Application Introductions ......................19 3-1 Parameter Overview ............................20 3-2 Parallel Setup Steps ............................
  • Page 7: Chapter 1 Overview Of Parallel Control Parallel Control Solution

    Chapter 1 Overview of Parallel Control Parallel Control Solution System Architecture Overview 1-1 Overview of Parallel Control 1-2 Model List 1-3 Accessories Overview...
  • Page 8: Overview Of Parallel Control

    The parallel solution model is suitable for AC motor drives with the same power of 220kW and above (C2000 Plus, C2000-HS and C2000-R). It addresses the need for capacity expansion in high-power control by enabling internal communication between two AC motor drives (master/ slave) for parallel expansion control.
  • Page 9: Model List

    Chapter 1 Overview of Parallel Control Parallel Control Solution 1-2 Model List Non-common DC bus parallel connection application selection AC Motor Drive Reactor Power Applicable AC Motor Rated Current* Inductance Value Applicable Reactor Selection (kW) Drive Models (μH) VFD2200C43x DR505LP004P 4.35 VFD2200C43x-HS DR505LP004P...
  • Page 10 The carrier frequency is default. Increasing the carrier frequency requires a reduction in current. Refer to Section 9-7 Derating Curve for details in C2000 Plus User Manual. The AC motor drive should operate in derating current when its control method is set to FOC Sensorless, TQC+PG, TQC sensorless, PM+PG or PM sensorless.
  • Page 11 Chapter 1 Overview of Parallel Control Parallel Control Solution C2000-HS Frame VFD-_ _ _ C43x-HS 2200 3550 Rated Output Capacity (kVA) Rated Output Current (A) Applicable Motor Output (kW) Applicable Motor Output (HP) 120% of rated output current: 1 minute for every 5 minutes; Overload Capacity 160% of rated output current: 3 seconds for every 30 seconds Max.
  • Page 12 Chapter 1 Overview of Parallel Control Parallel Control Solution C2000-R Frame VFD_ _ _ _ C43A-00R 2200 2500 2800 3150 3550 4500 Rated Output Capacity (kVA) Rated Output Current (A) Applicable Motor Output (kW) Applicable Motor Output (HP) Overload Capacity 120% of rated output current: 1 minute for every 5 minutes Max.
  • Page 13: Accessories Overview

    In C2000 series, the optical fiber communication card is installed in Slot 2 by default. If you need to install the communication card in Slot 1, contact Delta for further information. ⚫ Delta provides two length options for the required fiber optic communication cables. Fiber Optic Cable Model Name...
  • Page 14 Chapter 1 Overview of Parallel Control Parallel Control Solution Light Meanings Item SDP3 SDP4 SDP5 SDP6 Light Colors Green Green Green Blinking / Steady Steady Blinking Steady Steady MCU and FPGA Fiber Card Configuration Representation FPGA Power Communication Communication Data If the green light is If the green light If the green light is ON, the...
  • Page 15 During the parallel control, if there is no reactor installed on the output side, some of the current from the drive flows into the parallel drive and causes circulating current. Install an output reactor can prevent the above circulating current occurs. Refer to the user manual of each drive models in Delta Download Center for reactor selections.
  • Page 16 Chapter 1 Overview of Parallel Control Parallel Control Solution Figure 1-3 Rated Inductance Saturated Parallel Circulating Consumption Dimension Current Value Current Current Reactor Delta # (mm) Certification (μH) (Arms) As shown in DR616LP004P 3.77 the figure Pass above Table 1-10...
  • Page 17 Chapter 1 Overview of Parallel Control Parallel Control Solution Figure 1-4 Rated Inductance Saturated Parallel Circulating Consumption Dimension Current Value Current Current Reactor Delta # (mm) Certification (μH) (Arms) As shown in DR770LP003P 2.93 1155 126.7 the figure Pass above...
  • Page 18 Chapter 1 Overview of Parallel Control Parallel Control Solution Figure 1-5 Rated Inductance Saturated Parallel Circulating Consumption Dimension Current Value Current Current Reactor Delta # (mm) Certification (μH) (Arms) As shown in DR930LP002P 2.41 1395 the figure Pass above Table 1-12...
  • Page 19 Chapter 1 Overview of Parallel Control Parallel Control Solution Figure 1-6 Rated Inductance Saturated Parallel Circulating Consumption Dimension Current Value Current Current Reactor Delta # (mm) Certification (μH) (Arms) As shown in DR1212LP002P 1212 1.82 1818 209.5 the figure Pass...
  • Page 20 Chapter 1 Overview of Parallel Control Parallel Control Solution [This page intentionally left blank]...
  • Page 21: Wiring

    Chapter 2 WiringParallel Control Solution Wiring 2-1 System Wiring Diagram...
  • Page 22 Refer to the nameplate information in the User Manual of each models for details: ⚫ C2000 Plus User Manual (refer to Section 1-1): https://downloadcenter.deltaww.com/downloadCenterCounter.aspx?DID=22212&DocPath=1&hl=en-US ⚫ C2000-HS User Manual (refer to Section 1-1): https://downloadcenter.deltaww.com/downloadCenterCounter.aspx?DID=42836&DocPath=1&hl=en-US...
  • Page 23: System Wiring Diagram

    Chapter 2 WiringParallel Control Solution 2-1 System Wiring Diagram Supply power according to the rated Power input power specifications indicated in the terminal manual. There may be a large inrush current NFB or fuse during power on. Switching the power ON/OFF on the primary side of the electromagnetic contactor can turn the drive ON/OFF, but Electromag-...
  • Page 24 Chapter 2 WiringParallel Control Solution [This page intentionally left blank]...
  • Page 25: Chapter 3 Parallel Application Introductions Parallel Control Solution

    Chapter 3 Parallel Application Introductions Parallel Control Solution Parallel Application Introductions 3-1 Parameter Overview 3-2 Parallel Setup Steps...
  • Page 26: Parameter Overview

    Chapter 3 Parallel Application Introductions Parallel Control Solution 3-1 Parameter Overview The following describes the parameters related to parallel connection:  You can set this parameter during operation 00-62 Six-Phase Motor Master and Slave Settings Default: 0 Settings 0–2 0: Single unit mode 1: Master mode 2: Slave mode 00-63...
  • Page 27: Parallel Setup Steps

    Chapter 3 Parallel Application Introductions Parallel Control Solution 3-2 Parallel Setup Steps 3-2-1 C2000 Series Settings The following is the setting process and descriptions of C2000 series parallel connection, re-power the drive after completing the set up. 3-2-1-1 C2000 Series Tuning ⚫...
  • Page 28: Motor Parameter Autotuning

    Chapter 3 Parallel Application Introductions Parallel Control Solution 3-2-1-4 Motor Parameter Autotuning ⚫ In parallel model, the master drive must switch back to single unit mode before executing motor parameter autotuning, Pr.00-62 = 1 (master mode) changes to 0 (single unit mode). Be aware that the output side wiring of the Slave must be removed (as shown in the following figure), otherwise there is a risk of the Slave boosting the voltage.
  • Page 29: Chapter 4 Fault Codes And DescriptionsParallel Control Solutions

    Chapter 4 Fault Codes and DescriptionsParallel Control Solutions Fault Codes and Descriptions Summary of Fault Codes ID No. Fault Name Slave Error (SLEr) SPI Tx Error (CdE1) Fiber Card UART Error (PUtE) SPI Rx Error (CdE2) PCOM Data Loss (PDlE) PCOM Torque Error (PSTq)
  • Page 30 Chapter 4 Fault Codes and DescriptionsParallel Control Solutions Display on LCD Keypad Fault Name Fault Descriptions Slave Error Slave error: this fault code only displays on the Master (SLEr) drive. Action and Reset Action Condition Slave Error Action Time Act immediately Fault Treatment Parameter Reset Method Manual reset...
  • Page 31 Reset Method Manual reset Reset Condition The drive and fiber card reconnect normally Record Cause Corrective Actions 1. Check if the fiber card is installed firmly. Fiber card abnormal 2. If the issue persists, replace the fiber card, and contact Delta.
  • Page 32 Communication between master and slave fiber cards has been restored Record Cause Corrective Actions Abnormality between fiber cards or 1. Check if the fiber cards or fiber cables is installed firmly cables 2. If the issue persists, replace the fiber cards and cables, and contact Delta.
  • Page 33 The drive and fiber card reconnect normally Record Cause Corrective Actions Abnormality between fiber cards or Check if the fiber cards or fiber cables is installed firmly cables If the issue persists, replace the fiber cards and cables, and contact Delta.
  • Page 34 Chapter 4 Fault Codes and DescriptionsParallel Control Solutions Display on LCD Keypad Fault Name Fault Descriptions PCOM Data Loss UART disconnect between fiber cards (PDIE) Action and Reset Action Condition UART disconnect between fiber cards Action Time Act immediately Fault Treatment Parameter Reset Method Manual reset Reset Condition...
  • Page 35 Chapter 4 Fault Codes and DescriptionsParallel Control Solutions Display on LCD Keypad Fault Name Fault Descriptions PCOM Torque Error Abnormal torque distribution (PSTq) Action and Reset Action Condition More than 50% difference in torque distribution between master and slave Action Time Act immediately Fault Treatment Parameter Reset Method...
  • Page 36 Chapter 4 Fault Codes and DescriptionsParallel Control Solutions [This page intentionally left blank]...

This manual is also suitable for:

C2000-hsC2000-r