4-3-3

Extended Control I/O (101/151/153)

Extended Control I/O is OMRON's unique Remote I/O not defined in the CompoNet specifications.
This type of Remote I/O is optimized for the input/output function of inverters, allowing you to select
each input/output function by setting a multi-function input/output parameter.
Extended Control I/O Output
Assembly ID: 101 Dec (65 hex)
 Output Format (CS1/CJ1-series → Inverter)
Word
Byte
No.
No.
n
0
1
n + 1
2
3
n + 2
4
5
n + 3
6
7
 Output Bit/Data Details
Name
FW
Forward/Stop
RV
Reverse/Stop
CI3 to
Multi-function
CI7
Input
CI8
Multi-function input
[8]
EXT
External trip
RS
Reset
CR
Multi-function Con-
tact Output
CO1,
Multi-function
CO2
Output
CO3 to
Multi-function Out-
CO5
put
CompoNet Communications Unit User's Manual (I582-E1)
bit 7
bit 6
bit 5
CI8
CI7
CI6
CO2
CO1
CR
Rotation Speed Reference (Low byte)
Rotation Speed Reference (High byte)
Torque Reference (High byte)
Torque Compensation Bias (Low byte)
Torque Compensation Bias (High byte)
0: Stop
1: Forward
0: Stop
1: Reverse
Follow the setting of each multi-function input (C003 to C008).
0: OFF
1: ON
Follows the setting of each multi-function input (C003 to C008).
0: OFF
1: ON
0: –
1: External fault
0: –
1: Fault reset
If a multi-function output (C021 to C026) is set to 63 (OPO: Option), you can
control the corresponding inverter multi-function output.
0: OFF
1: ON
If a multi-function output (C021 to C026) is set to 63 (OPO: Option Board), you
can control the corresponding inverter multi-function output.
0: OFF
1: ON
Bit Allocation
bit 4
bit 3
CI5
CI4
CO5
CO4
Torque Reference (Low byte)
Description
4 Remote I/O
bit 2
bit 1
bit 0
CI3
RV
FW
CO3
RS
EXT
4 - 13