8
Set the area type, first address, and allocation size for each allocation area.
• Area type: In [Area], select the memory type of the CPU Unit.
• First address: In [Address], select the first address of the area.
• Allocation size: In [Node], set the number of occupied node addresses.
For the CompoNet Communications Unit, the number of occupied node addresses can be
calculated as No. of I/O words occupied by Remote I/O x No. of Units.
Data and Participation Flags/Communications Error Flags can be allocated to the following
areas.
Data
WORD OUT
WORD IN
BIT OUT
BIT IN
Participation
Flags/
Communications
Error Flags
Word Unit
Bit Unit
9
Click the [Apply] button.
The settings are saved and you return to the [General] tab.
10
On the [General] tab, click the [Transfer [PC to Unit]] button.
The settings are transferred to the Master Unit.
11
Set CX-Integrator offline and power off the CompoNet Communications Unit
(CS/CJ-series).
12
Power on the inverter(s) and configure the following settings according to 3-1 Inverter
Configuration on page 3-2.
• Set the node address. According to Setting Slave Node Addresses on page 3-15, set the
rotary switches or CompoNet node address (P190).
• Set the type of Remote I/O. Set inverter parameter P046 (Assembly Instance No.) that suits
your application.
CompoNet Communications Unit User's Manual (I582-E1)
Area
(I/O Memory Area Type)
CIO, DM, WR, or HR area
Area
(I/O Memory Area Type)
CIO, DM, WR, or HR area
Address
(First allocation address
for each specified area
type)
Any address can be set for
each area type.
Address
(First allocation address
for each specified area
type)
Any address can be set for
each area type.
3 Network Startup
Number of Nodes
(No. of occupied node
addresses)
64 max.
64 max.
128 max.
128 max.
Allocated Contents
Word slave status (1 word),
Setting parameter (1 word),
Participation/Communica-
tions Error Flags (16 words)
Bit Slave Participation
Flags/Communications Error
Flags (32 words)
3 - 19