Outline Of Message Function And Response - Omron CompoNet MX2 Series User Manual

Inverter, communications unit
Hide thumbs Also See for CompoNet MX2 Series:
Table of Contents

Advertisement

5-3
Outline of Message Function and
Response
When using the Message function, the CompoNet Communications Unit on the inverter returns the
response in the following method.
In CompoNet communications, data is sent/received basically in units of 1 byte (8 bits).
For single-word (16-bit) data, the order of high and low bytes will be reversed due to the following rea-
son.
• Data on communications lines: Sent/received in order of low byte to high byte.
• Data processed in programmable controller when issuing a command etc.: Sent/received in order
of high byte to low byte.
Therefore, for attributes indicated as "word" in the Size column of the tables provided in A-1 General
Object Specifications on page A-2 and A-2 AC Drive Object Specifications on page A-11, create attach-
ment data or read response data in reverse order of high and low bytes.
Precautions for Correct Use
Precautions for Correct Use
For Remote I/O, this need not be considered because high and low bytes will be reversed
automatically.
 Command Format
28
02
Command Code
 Response Format
Normal response
28
28
28
02
02
02
Command Code
Error response
28
28
28
02
02
02
Command Code
Send failure or timeout
28
02
Command Code
CompoNet Communications Unit User's Manual (I582-E1)
Destination
Service Code
node address
00
00
End Code
No. of received bytes
00
00
End Code
No. of received bytes
End Code
5 Message Communications
Class ID
Instance ID
Source
Service Code
node address
00
Source
Service Code
node address
(0094 hex fixed)
Max. 32 bytes
Service Data
(Attribute No.
or Attribute No.
+ Write Data)
Max. 32 bytes
Service Data
(Read Data)
94
Error Code
5 - 7
5

Advertisement

Table of Contents
loading

Table of Contents