Harmony Series H2 Mortise Lock
7 Outside Cylinder Installation
1. Verify orientation of cylinder so that SARGENT logo is right-side up (Fig. 7A).
2. Withdraw the key about 25% out of the cylinder before inserting into the escutcheon (Fig. 7B).
3. Use the key to rotate the cylinder clockwise until it is flush at the bottom and the SARGENT
logo is right-side up.
Do not attempt to tighten all the way.
4. Tighten the cylinder clamp set screw to prevent
unscrewing of the cylinder (Fig. 7C).
5. Test cylinder function:
• 70/71 Function: Key retracts latch.
• 80/81 Function: Key retracts latch
and projects/retracts deadbolt.
• Ensure smooth operation of
latchbolt and deadbolt.
NOTE: Use lever handle holes
to manipulate mortise to ease thread engagement of cylinder.
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
Outside of Door
Fig. 7B
Position cylinder so that the
SARGENT logo is right-side up.
Correct
Incorrect
Fig. 7A
Fig. 7C
13
Cylinder Set Screw
Phillips
Screwdriver