FLUE INSTALLATION CONFIGURATION

FLUE INSTALLATION

For all installations, only "Abey
appliance MUST NOT be flued into 'natural draft' flue system or terminate into a chimney.
For vertical and vertical offset
flue installations a baffle plate
will need to be fitted
Vertical
Flue
Installation
Correct baffle must be used for vertical installations refer to page 28 for details.
CAUTION
Rinnai Australia
®
" Flue components shown in these instructions MUST BE used. This
Vertical
Offset Flue
Installation
23
All measurements are in (mm)
Total Flue length not to
exceed 5400
Only one 90° change
of direction allowed on
any installation.
Max 800
Min 300
For
horizontal
installations no baffle
plate is required
Horizontal
Flue
Installation
flue
Installation Manual