How to Configure
1. Set GradationCompressionMode to On to enable the function.
2. Select a value for GradationCompression1stKneePoint to indicate where to start applying
compression on the intensity values coming from the sensor. The knee point is specified as a
percentage of the maximum digital value of the 8-bit compressed output (255).
3. Select a value for GradationCompression1stGain in order to set the slope angle at the first
knee point. Available values range from 0 dB (no compression) to -66 dB.
4. Use GradationCompression2ndKneePoint and GradationCompression2ndGain to define
an additional compression segment.
Note: 2ndKneePoint must be specified with a value greater than 1stKneePoint. The
maximum value is 200% when
SensorDigitizationBits is set to 12Bits.

Examples

The following examples show how Gradation Compression knee points and gain can be calculated
and applied.
SensorDigitizationBits
SensorDigitizationBits
= 10Bits
- 61 -
User Manual (Ver. Tentative) - Main Functions
is set to 10Bits, and 800% when