IAI GOX-5105M-5GE User Manual page 95

Tentative version
Table of Contents

Advertisement

GOX-5105MC-5GE | GOX-8105MC-5GE | GOX-12405MC-5GE | GOX-16205MC-5GE | GOX-20405MC-5GE | GOX-24505MC-5GE
Image Format Control Item
GradationCompression
1stKneePoint
GradationCompression1stGain
GradationCompression
2ndKneePoint
GradationCompression2ndGain
TestPattern
OverlayMode
Related Topic:
Overlay Mode
Setting
Default
Range
Value
Set the first knee point of the sensor's gradation compression
function in percentage.
-
50
Setting Range (%): 0, 6.25, 12.5, 25, 50, 100
Max Value: 0 or the GradationCompression2ndKneePoint value,
whichever is smaller.
Set the first knee compression rate for the sensor's gradation
compression function in dB.
-
0
Setting Range (dB): 0, -6, -12, -18, -24, -30, -36, -42, -48, -54, -60,
-66
Set the second knee point of the sensor's gradation compression
function in percentage.
-
100
Setting Range (%): 6.25, 12.5, 25, 50, 100, 200, 400, 800
Min Value: GradationCompression1stKneePoint. However, when
GradationCompression1stKneePoint is set to 0, Min = 6.25
Set the second knee compression rate for the sensor's gradation
compression function in dB.
-
0
Setting Range (dB): 0, -6, -12, -18, -24, -30, -36, -42, -48, -54, -60,
-66
Select the test image.
0: Off (Default)
-
0: Off
1: GreyHorizontalRamp
4: HorizontalColorBar (Color models only)
You can check the target area by reducing the brightness of the
non-target area to 50%.
0: Off (Default)
-
0: Off
1: MultiRoiAreaMode - Check the active area on MultiROI.
2: ALCAreaMode - Check the photometry area on ALC.
3: AWBAreaMode - Check the photometry area on AWB.
- 95 -
User Manual (Ver. Tentative) - Setting List