IAI GOX-5105M-5GE User Manual page 104

Tentative version
Table of Contents

Advertisement

GOX-5105MC-5GE | GOX-8105MC-5GE | GOX-12405MC-5GE | GOX-16205MC-5GE | GOX-20405MC-5GE | GOX-24505MC-5GE
Pulse Generator Item
PulseGeneratorEndPointMs
(ms)
PulseGeneratorPulseWidth
(ms)
PulseGeneratorRepeat
Count
PulseGeneratorClear
Activation
PulseGeneratorClear
Source
PulseGeneratorClear
SyncMode
Setting Range
Default Value
-
50
-
50
0~ 255
0
0: Off
1: Rising Edge
2: Falling Edge
0: Off
3: Level High
4: Level Low
-
24: Line5 Opt In1
0:Async Mode
0:Async Mode
1:Sync Mode
User Manual (Ver. Tentative) - Setting List
Set the start point of the Low interval in milliseconds. When
the counter reaches this value, the output will be 0. The
setting range varies depending on the ClockPreScaler
value.
PulseGeneratorEndPointMs = 1/PulseGeneratorClock *
PulseGeneratorEndPoint
Display the High interval width of the pulse in milliseconds.
The duration between the Start Point and End Point is
calculated. The setting range varies depending on the
ClockPreScaler value.
PulseGeneratorPulseWidth = 1/PulseGeneratorClock *
(PulseGeneratorEndPoint - PulseGeneratorStartPoint)
Set the repeat count for the counter. When this is set to 0, a
free counter is enabled with no repeat limit.
Set the clear signal condition for the count clear input of the
pulse generator.
Select the count clear input signal source.
1: AcquisitionActive
2: FrameActive
4: ExposureActive
5: FVAL
7-10: PulseGenerator0-3(※)
11-14: UserOutput0-3
24: Line5 Opt In1
36: Nand0 Out
37: Nand1 Out
43: AcquisitionTriggerWait
44: FrameTriggerWait
Note: (※)Disabled if the PulseGenerator is selected in
PUlseGeneratorSelector.
Select the sync mode for the count clear input signal.
- 104 -