Section 4

Force Transmit Procedure

This diagnostic software routine allows the user to "force" a transmitting condition that can be use to
search for an amplitude level (ALC) when Detection Fault or Low Signal alarms are present. The routine
forces the flowmeter to generate constant transmit bursts while reporting current receive signal strength
for the user. To initiate the Force Transmit function, refer to the example shown below.
1. After [Install] is selected press <ENT>. While the flowmeter is going through the drives (see menu
screen below), press the <ALT> and <MENU> keys simultaneously.
Siemens
Key Install after mounting transducers
Install Path
Transducer Model
Transducer Size
Xdcr Mount Mode
Spacing Offset
Number Index
Spacing Method
Ltn Value (in)
Install Completed?
Zero Flow Adjust
Pick/Install Xdcr
NOTE: The <ALT> and <MENU> keys must be pressed before the flowmeter scans through all
the drives, or the selection of the detection mode and the Force Transmit function must
be initiated again.
2. A typical menu screen will appear as shown below and indicate the current ALC (e.g., 50).
This ALC number indicates the current receive signal strength and can be used for further diagnostic
purposes.
Siemens
Dual Path
ForceN
fx=8
Install Path
Transducer Model
Transducer Size
Xdcr Mount Mode
Spacing Offset
Number Index
Spacing Method
Ltn Value (in)
Install Completed?
Zero Flow Adjust
Pick/Install Xdcr
Dual Path
SITE1
1
1011G Universal
B3
Direct
Minimum
4
Track 1012TP
0.217
No
Channel Not Setup
SITE1
m=7
ALC=50
1
1011G Universal
B3
Direct
Minimum
4
Track 1012TP
0.217
Install
Channel Not Setup
Siemens
Drive 11
Install Path
Transducer Model
Transducer Size
Xdcr Mount Mode
Spacing Offset
Number Index
Spacing Method
Ltn Value (in)
Install Completed?
Zero Flow Adjust
Pick/Install Xdcr
Siemens
Install Path
Transducer Model
Transducer Size
Xdcr Mount Mode
Spacing Offset
Number Index
Spacing Method
Ltn Value (in)
Install Completed?
Zero Flow Adjust
Pick/Install Xdcr
4-26
1010GCNFM-3C
Dual Path
SITE1
1
1011G Universal
B3
Direct
Minimum
4
Track 1012TP
0.217
Install
Channel Not Setup
Dual Path
SITE1
1
1011G Universal
B3
Direct
Detection Fault
Press [ENT]
Install
Channel Not Setup