The Flow/Total Units Menu; Totalizer Controls - Siemens SITRANS FUG1010 IP65 NEMA 4X Instruction Manual

Ultrasonic flowmeters
Hide thumbs Also See for SITRANS FUG1010 IP65 NEMA 4X:
Table of Contents

Advertisement

Section 4
4.6

THE FLOW/TOTAL UNITS MENU

The [Flow/Total Units] menu is available after selecting a flowmeter type and measurement channel.
Use the [Flow/Total Units] menu to select mass and volumetric flow units and an associated time base.
Independent volume/mass units can be selected by the Totalizer. After making your selections, a view-
only menu cell shows the resultant scaling. Another menu cell lets you adjust the output resolution by
selecting a display range.
This system provides three totalizer display modes:
POSFLOW ............................. Positive (forward) flow total only
NEGFLOW ............................ Negative (reverse) flow total only
NETFLOW ............................. The net of the Positive and Negative flow (default)
The flow computer stores positive and negative accumulations in separate independent registers. It
develops the NETFLOW output by summing the positive and negative totalizer registers. You use the
keypad's function and numeric keys to control the flow totalizer registers.
Use this menu cell to select
either volumetric or mass flow
rate units .
Use this menu cell to select a
time base for the flow rate
units.
Use this menu cell to select a
range for the flow rate display
screen .
Use this menu cell to select
either volumetric or mass flow
total units .
Use this menu cell to set the
resolution of the totalizer .
TOTALIZER CONTROLS (the 'n' in <Fn> = channel number)
<Fn><1>
CLEAR (also clears overflow)
<Fn><2>
NOTOT(Totalizer Freeze)
<Fn><3>
LAPTOT(Totalizer snapshot)
<Fn><4>
CLEAR (Batch/Tot Register)
Siemens
2 Channel [1]
Choose desired Flow rate volume units
Flow Volume Units
Cubic Feet
Std. Vol Corr
No
Flow Time Units
HR
Flow Display Range
Autorange
Flow Display Scale
KCU FT/HR
Total Volume Units
Cubic Feet
Totalizer Scale
KCU Ft
Total Resolution
00000x00
Totalizer Mode
NETFLOW
Batch/Sample Total
0.000
Flow/Total Units
Resetting the Totalizer registers clears all total data accu-
mulated during operation.
Note: In Dual-Beam mode, the Totalizer operates only on
the virtual system channel (Ch 3). Therefore, in this case,
the CLEAR trigger would be <F3> <1>
Invoking the NOTOT command disables the Totalizer. To-
talization will not resume until you repeat the Fn and Nu-
meric 2 key sequence. When you activate NOTOT, an N
precedes the TOTAL symbol (i.e., [NTOTAL]) on the LCD
Screen.
The LAPTOT command freezes the Totalizer screen dis-
play. However, the flow computer will continue to update
its internal registers. The flow computer will show the cur-
rent total when you repeat the F1 - Numeric 3 key sequence.
When you activate LAPTOT, an L precedes the TOTAL
symbol (i.e., [LTOTAL]) on the LCD Screen.
Clears the Batch Sample totalizer register. See Batch/
Sample Tot.
4-35
SITE1
Use these menu cells
to set the scaling for the
flow rate and flow total
outputs.
Use this menu cell to
select how the totalizer
accumulates flow.
1010GCNFM-3C
Use this menu cell to
enable Standard Volume
Compensation of volumetric
flow rate and total volume.
Use this menu cell to enter a
volume accumulation for the
batching or sampling totalizer
relay trigger.