Specifications

Environmental specifications

Specification
Temperature range*
Operating
Shipping
Maximum wet bulb temperature 28°C (82.4°F)
Relative humidity
(noncondensing)**
Operating
Nonoperating
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3,048 m
(10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 kPa.

Server specifications

Specification
Height
Depth
Width
Weight (maximum: two
processors, eight hard drives)

Hot-plug power supply calculations

For hot-plug power supply specifications and calculators to determine electrical and heat loading for the
server, see the Hewlett Packard Enterprise Power Advisor website
(http://www.hpe.com/info/rackandpower).
Value
10°C to 35°C (50°F to 95°F)
-40°C to 70°C (-40°F to 158°F)
10% to 90%
5% to 95%
Value
16.82 cm (6.62 in)
81.91 cm (32.25 in)
22.08 cm (8.69 in)
21.32 kg (47.00 lb)