B. ELECTRICAL MOTOR SPECIFICATIONS:
(H.P. = Horse Power; RPM = Revolutions Per Minute; FLA = Full Load Amperes; LRA = Locked Rotor Amperes @
Start Up)
ALTERNATING CURRENT SYSTEMS:
Single Phase Alternating Current:
VAC
Hz
110
50
220
50
115
60
230
60
Three Phase Alternating Current:
VAC
Hz
220
50
380
50
230
60
460
60
C. RECOMMENDED CIRCUIT BREAKER SUPPLYING POWER TO SYSTEM AMPERAGE
RATING:
Operating
AC Voltage
110 - 115 VAC
220 - 230 VAC
220 VAC
380 VAC
460 VAC
D. RECOMMENDED POWER WIRE SIZE TO Aqua Matic SYSTEM and Pump Motors:
RECOMMENDED POWER WIRE SIZE TO Aqua Matic SYSTEM:
Operating
Phase
Voltage
110-115 VAC
Single
220-230 VAC
Single
220-230 VAC
Three
380 VAC
Three
460 VAC
Three
High Pressure Pump Motor
H.P
RPM
FLA
3
2850
23
3
2850
11.5
3
3450
25.4
3
3450
12.7
High Pressure Pump Motor
H.P
RPM
FLA
2.5
2850
7.9
2.5
2850
4.6
3
3450
7.6
3
3450
3.8
Recommended
Phase
Circuit Breaker
Single
50 Ampere
Single
25 Ampere
Three
15 Ampere
Three
10 Ampere
Three
10 Ampere
Maximum
Recommended Minimum Wire Size for Length of run
Load
10 Ft / 3 meter
34.8 Ampere
10 AWG / 6 mm
17.4 Ampere
12 AWG / 4 mm
10.4 Ampere
14 AWG / 2.5 mm
6.1 Ampere
14 AWG / 2.5 mm
5 Ampere
14 AWG / 2.5 mm
section 9 page 4 of 36
Booster Pump Motor
LRA
H.P
RPM
89
.5
2850
44
.5
2850
86
.5
3450
43
.5
3450
Booster Pump Motor
LRA
H.P
RPM
24.9
.5
2850
14.4
.5
2850
23.8
.5
3450
11.9
.5
3450
25 Ft / 8 meter
2
8 AWG / 10 mm
2
12 AWG / 4 mm
2
14 AWG / 2.5 mm
2
14 AWG / 2.5 mm
2
14 AWG / 2.5 mm
FLA
LRA
7.4
20
3.7
10
9.4
20
4.7
10
FLA
LRA
2.5
8.2
1.5
4.7
2.4
7.9
1.2
3.9
50 Ft / 15 meter
2
2
8 AWG / 10 mm
2
12 AWG / 4 mm
2
2
14 AWG / 2.5 mm
2
2
2
14 AWG / 2.5 mm
2
14 AWG / 2.5 mm
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents