6. Although the system is producing "Product Water", the Product Water may not be "Potable" for up to 30
minutes. The salinity of the Product Water diminishes gradually, until it reaches the factory setting at which
time the Touch Screen will change from SALINITY UNSAFE to SALINITY SAFE. When the SALINITY SAFE
message appears the Product Water salinity has diminished to the Set point or lower.
SALINITY UNSAFE simply means that the dissolved solids in the Product Water have not yet decreased to the
set point. In situations where the water is necessary, regardless of the exact PPM, the DIVERSION VALVE
may be activated to route the Produce water to the boat's potable water storage tank. This can be
accomplished at the Touch Screen or manually at the valve.
The 3-Way Product Water Diversion Valve may now be activated by Touching DIVERSION
VALVE. This will cause the U.V. Sterilizer [44] to energize, and the 3-Way Product Water
Diversion Valve [41] to energize which will cause potable water to be diverted by the 3-way
Product Water Diversion Valve to the "Potable" (good water) position and into the Post
Filtration components onward to the Ship's Storage Tank [46].
7th Screen
057
Touch DIVERSION VALVE
7. All System readings, pressures, flows, and salinity will be displayed on the Main Touch Screen.
8. The Remote Touch Screen will be blocked during operation in the Manual Mode.
Screen
Manual Operation
9. If any abnormality develops PRESS STOP and correct the problem.
10. Check for:
a. A constant feed water flow.
b. A consistent system pressure.
c. Leaks in the system.
d. Abnormal noises or other occurrences.
11. IMPORTANT Information prior to Stopping the System:
a. FREEZING TEMPERATURE WARNING: Freezing temperatures, temperatures below 32º Fahrenheit / 0º
Celsius, will cause extensive damage to the Aqua Matic as the water expands within the System during the
freezing process. Resulting damage to the Aqua Matic System caused by freezing temperatures is
attributed to improper operator care and protection, is the liability of the operator, and is not covered by
the Sea Recovery warranty.
DO NOT subject the Aqua Matic to temperatures below 32º Fahrenheit / 0º Celsius unless the Aqua Matic
has been rinsed with a solution of product water with twenty percent food grade glycerin (propylene glycol)
as described in Section 6 of this Owner's Manual.
b. LONG TERM STORAGE CAUTION: If the System will not be operated for an extended period of time, 3
months or longer, refer to Section 6 of this Owner's Manual for Long Term Storage Procedures.
c. SHORT TERM STORAGE CAUTION: If the System will not be operated for up to a few weeks the System
should be rinsed with fresh water. Refer to Section 6 of this Owner's Manual for Short Term Fresh Water
Rinsing Procedures.
Remote Touch Screen display during access into the Service Menu and during
014
section 5 page 13 of 18
Aqua Matic 450-1800 Rev. A