Touch START
All Operating Screens will include the Automatic Fresh Water Flush components or not depending on if this option was
set in the System Control logic. Both Screens are shown for the remainder of the commissioning operation:
3
Screen
or
rd
045
Info
BOOSTER PUMP ON
5
Screen
or
th
047
Info
SETTING PRESSURE
7
Screen
or
th
048
Info
SYSTEM OK Press here to see details
13. A new System may take up to 30 minutes to purge the R.O. Membrane Element of the storage chemical that it
was shipped in, and produce Potable Water. Even after the storage chemical is purged, although the system is
producing "Product Water", the Product Water may not be "Potable" for up to 30 minutes. The salinity of
the Product Water diminishes gradually, until it reaches the factory setting at which time the Touch Screen
will change from TDS HIGH Screen to the SYSTEM OK Screen. When the SYSTEM OK Screen appears the
Product Water is Potable and is diverted by the 3-way Product Water Diversion Valve [41] to the "Potable"
(good water) position and into the Post Filtration components onward to the Ship's Storage Tank [46]. At this
If the READY TO START Screen looks like this, without the Automatic Fresh Water Flush
Charcoal Filter [51] then the System Control Logic has been set without the Automatic Fresh
Water Flush option. If the Automatic Fresh Water Flush option is not installed this screen is
correct. If the Automatic Fresh Water Flush option is installed this screen is not correct, refer
to section 3 of this Owner's Manual to properly set the System Control Logic .
If the READY TO START Screen looks like this, with the Automatic Fresh Water Flush
Charcoal Filter [51] then the System Control Logic has been set with the Automatic Fresh
Water Flush option. If the Automatic Fresh Water Flush option is installed this screen is
correct. If the Automatic Fresh Water Flush option is not installed this screen is not correct,
refer to section 3 of this Owner's Manual to properly set the System Control Logic.
Screen
051
Info
Screen
053
Info
Screen
054
Info
section 4 page 11 of 16
4
Screen
or
th
046
Info
HIGH PRESSURE PUMP ON
6
Screen
or
th
089
Info
TDS HIGH
8
Screen
th
043
Info
SYSTEM INFORMATION
Aqua Matic 450-1800 Rev. A
Screen
052
Info
Screen
090
Info