1. SYSTEM COMMISSIONING NOTES:

Throughout this Manual, Numbers in [ brackets ] refer to the I.D. numbers Illustrated in the various Piping and
Interconnect Diagrams throughout this manual.
These Commissioning instructions must be carried out for initial start-up of a NEW system. For every day use
starting procedures, refer to Section 4 Operation.
Failure to follow these instructions exactly leads to system failure and causes damage to components within the
System. Read this section and other appropriate sections of the manual in order to gain familiarity with the
requirements of the system and functions of each component.
2. CHECK THE INSTALLATION TO ENSURE CONFORMANCE TO INSTRUCTIONS IN SECTION 2
OF THIS MANUAL:
1. Ensure that the installation has been properly performed as per the instructions in Section 2 of this Owner's
Manual. Do not rely on the installer's word, do not assume the Aqua Matic has been installed correctly.
WARNING: Damage caused to the system due to operation of an improperly installed system is attributed to
improper installation and subsequent operation, is the liability of the installer and the operator, and is not
covered by the Sea Recovery warranty.
Check each water connection to the system to ensure that the installer has properly connected and properly
routed each tube. Improper routing and any blockage in any line causes damage to the system. Improperly
connected or loose connected lines resulting in leaks causing damage is the liability of the installer and the
operator, and is not covered by the Sea Recovery warranty.
Do not assume and do not rely on the installer's word; check it yourself.
Make sure that the Electrical Power Source, boat's circuit breaker to the system, is switched "OFF".
Open the Electrical Control Box and check all electrical and electronic connections for proper wiring and
attachment. Refer to the wiring diagrams in Section 9 of this Owner's Manual.
After checking all wiring for correct and tight connection, close the Electrical Control Box.
Switch the Electrical Power Source, boat's circuit breaker to the system, to the "ON" position.
3. REVERSE OSMOSIS MEMBRANE ELEMENT:
Check to ensure that the Reverse Osmosis Membrane Element(s) is (are) installed within the Pressure Vessel(s).
CAUTION: Some systems are shipped WITHOUT the Reverse Osmosis Membrane Element. This is to
accommodate, for example, Boat Builders that install the system well in advance of commissioning the boat and
the Aqua Matic.
If the Reverse Osmosis Membrane Element has been installed, there will be a Reverse Osmosis Membrane
Element Serial Number tag, illustrated below, attached to the High Pressure Vessel. Find this Serial Number tag
to ensure that the R.O. Membrane Element has been installed.
If the R.O. Membrane Element Serial Number tag is missing or does not contain a serial number and date, then
immediately contact the company that sold the system to you, the installer, or Sea Recovery.