C. OPERATION IN THE MANUAL MODE
CAUTION: When the System is operated in the MANUAL Mode Safety features will still be controlled by the
System Logic, however AUTOMATED features will not be controlled by the System Logic and must
be controlled by the operator.
SAFETY features that will be controlled by the System Logic during MANUAL operation include:
Shut Down due to low feed pressure
Shut Down due to high operating pressure
Shut Down due to low feed flow
AUTOMATED features that will not be controlled by the System Logic during MANUAL operation, and must be
controlled by the operator include:
Booster Pump operation
High Pressure Pump operation
Operating Pressure adjustment
3-Way Product Water Solenoid Diversion Valve operation
Ultra Violet Sterilizer operation
Fresh Water Flush operation
Fresh Water Flush 7 day cycle
AUTOMATED features that will not be controlled by the System Logic during MANUAL operation, and are not
available to the operator include:
Automated Timer Shut Down
Automated Volume Shut Down
Remote Touch Screen operation
1. Position Valves:
VALVE
a. Inlet Sea Cock Valve [2]
b. Rinse Clean Inlet Valve [54]
c. Rinse Clean Outlet Valve [55]
d. Multi Media Filter [12] Valves
e. ANY auxiliary valve in the
Feed Line, Brine Discharge Line,
or Product Water Line
WARNING: If any auxiliary valve is installed in these lines, it will damage the Aqua Matic if left closed during
starting and/or operation of the system. The resulting damage to the system is attributed to improper
installation, is the liability of the operator, and is not covered by the Sea Recovery warranty.
2. Switch the Electrical Power Source, boat or home's circuit breaker to the system "ON".
3. After the control logic has initiated itself, the first interactive screen with the Sea Recovery and Aqua Matic
Logos will appear indicating that the System is ready to Start
4. After the System has started and proper operating pressure has been manually set by the operator, although the
system is producing "Product Water", the Product Water may not be "Potable" for up to 30 minutes. The
salinity of the Product Water diminishes gradually, until it reaches the factory setting at which time the Touch
POSITION
FULL OPEN
FROM SEA STRAINER TO FRESH WATER FLUSH VALVE
FROM BRINE DISCHARGE OF SYSTEM TO THRU HULL
DISCHARGE FITTING [35 or 36]
NORMAL OPERATION (see Illustration in Section 4 page 9)
FULL OPEN