Aqua Matic 450-1800 Rev. A
45. Product Water Connector attaches to
the Potable Water unpressurized
tank for connection of the Product
Water hose.
E. FRESH WATER FLUSH SECTION: Includes a Carbon
Filter and an Automatic Motor Actuated Ball Valve
that automatically flushes the system with fresh
water. This process is automatic at each shut down of
the system and repeats automatically every 7 days.
Fresh Water Flushing replaces the seawater in the
system with less corrosive fresh water, and this also
reduces the biological growth and subsequent decay
that naturally occur if the feed water (sea water) is not
flushed from the system with fresh water.
49. Fresh Water Flush 2-way solenoid valve
***automatically actuates at system shut down and
every 7 days there after to flush the system with
fresh water.
50. Fresh Water Flush Check
Valve *** prevents feed
water from entering the
fresh water line.
51. Fresh Water Flush
Charcoal Filter ***
removes chlorine, if
present, in the fresh
water prior to flowing
through the R.O.
Membrane Element.
52. Fresh Water Flush Check Valve *** routs the fresh
water through the system.
53. Cleaning Bucket ** can be any non ferrous container
capable of holding at least 10 U.S. Gallons of water.
This container is used during the R.O. Membrane
Element cleaning, storing, or winterizing process.
Elbow 90 Male
46***
47***
48***
49***
section 1 page 14 of 19
54. Rinse Clean Inlet Valve ***
These Optional Valves are available from Sea
Recovery mounted separately on singular individual
plates as shown in the illustration above on the left,
or together on a double plate as illustrated above on
the right.
The Rinse Clean Inlet Valve is used in conjunction
with the Rinse Clean Outlet Valve [43] simplifies the
storage and cleaning procedures by allowing the
operator to turn
a valve rather than disconnect a hose. Also used for a
manual fresh water flush if the Automatic Fresh
Water Flush System [40 & 41] is not installed. The
Rinse Clean Valves are available on single mounting
plates or together on a double valve mounting plate.
55. Rinse Clean Outlet Valve *** (optional) used in
conjunction with and identical to the Rinse Clean
Inlet Valve [42] simplifies the storage and cleaning
procedures by allowing the operator to turn a valve
rather than disconnect a hose.