Sea Recovery SRC Aqua Matic 450-1 Owner's Manual page 132

Hide thumbs Also See for SRC Aqua Matic 450-1:
Table of Contents

Advertisement

Aqua Matic 450-1800 Rev. A
B. OPERATION IN THE AUTOMATIC MODE
WITH the FRESH WATER FLUSH OPTION Installed and set:
1. Position Valves:
VALVE
a. Inlet Sea Cock Valve [2]
b. Rinse Clean Inlet Valve [54]
c. Rinse Clean Outlet Valve [55]
d. Multi Media Filter [12] Valves
e. ANY auxiliary valve in the
Feed Line, Brine Discharge Line,
or Product Water Line
WARNING: If any auxiliary valve is installed in these lines, it will damage the Aqua Matic if left closed during
starting and/or operation of the system. The resulting damage to the system is attributed to improper
installation, is the liability of the operator, and is not covered by the Sea Recovery warranty.
2. Switch the Electrical Power Source, boat or home's circuit breaker to the system "ON".
All Operating Screens will include the Automatic Fresh Water Flush components if the Fresh Water Flush Option
is installed and the control logic has been set to include the Fresh Water Flush Option.
3. After the control logic has initiated itself, the first interactive screen with the Sea Recovery and Aqua Matic
Logos will appear indicating that the System is ready to Start
4. After the System has started, although the system is producing "Product Water", the Product Water may not
be "Potable" for up to 30 minutes. The salinity of the Product Water diminishes gradually, until it reaches the
factory setting at which time the Touch Screen will change from TDS HIGH Screen to the SYSTEM OK
Screen. When the SYSTEM OK Screen appears, indicating that the Product Water is Potable, the Ultra Violet
Sterilizer [44] energizes. The Potable Water is then diverted by the 3-way Product Water Diversion Valve [41]
to the "Potable" (good water) position and into the Post Filtration components onward to the Ship's Storage
Tank [46].
All System readings, pressures, flows, and salinity will be displayed on the Touch Screen.
4. If any abnormality develops PRESS STOP and correct the problem.
5. During operation, check for:
a. A constant feed water flow.
b. A consistent system pressure.
c. Leaks in the system.
d. Abnormal noises or other occurrences.
POSITION
FULL OPEN
FROM SEA STRAINER TO FRESH WATER FLUSH VALVE
FROM BRINE DISCHARGE OF SYSTEM TO THRU HULL
DISCHARGE FITTING [35 or 36]
NORMAL OPERATION (see Illustration in Section 4 page 9)
FULL OPEN
section 5 page 8 of 18