6. Function Tests of Electric Components:
PRIOR TO ASSUMING THAT AN ELECTRICAL COMPONENT IS BROKEN OR NON FUNCTIONAL PERFORM
A FUNCTION TEST TO DETERMINE IF IT IS OPERABLE OR NOT.
Function Tests should be performed as part of the commissioning procedure. Function tests can be performed
from the Touch Screen for the following Electrical Components:
• Booster Pump [7] Electric Motor
• High Pressure Pump [25] Electric Motor
• Diversion Valve [41] energize solenoid
• Fresh Water Flush Valve [49] energize solenoid
• Back Pressure Regulator [32] Electric Motor Actuator
• U.V. Sterilizer [44] Ballast and Lamp
1
Screen
2
st
nd
007
Touch the Logo
Touch MENU
a. ELECTRIC MOTOR ROTATIONAL CHECK:
Ask an assistant to view the fan section of the
Booster Pump Motor [7] and
High Pressure Pump Motor.[25]
while you "Jog" each of these
electric motors. These
Illustrations show the proper
rotation of each electric motor.
Rotation is clockwise when
viewing the back of the electric
motor (fan), counter clock
wise when viewing the front of the pump
b. AT THIS TIME CHECK THE FUNCTION OF THE FOLLOWING ELECTRICAL COMPONENTS:
BOOSTER PUMP: Booster Pump [7] Electric Motor will Jog momentarily. At the Controller Printed
Circuit Board the CONTROL STATUS LED "BP" will illuminate momentarily.
HP PUMP: High Pressure Pump [25] Electric Motor will Jog momentarily. At the Controller Printed
Circuit Board the CONTROL STATUS LED "HP" will illuminate momentarily.
DIVERSION VALVE: 3-Way Product Diversion Valve [41] Solenoid will energize momentarily. At the
Controller Printed Circuit Board the CONTROL STATUS LED "DV" will illuminate momentarily.
FWF VALVE: Fresh Water Flush Solenoid Valve [49] will actuate to the Fresh Water Flush position.
Pressing the switch a second time will cause the Fresh Water Flush Solenoid Valve to revert to the
Normal Feed position. At the Controller Printed Circuit Board the CONTROL STATUS LED "FWF"
will illuminate momentarily.
BPR IN: Back Pressure Regulator [32] Motor Actuator will rotate clock wise momentarily. At the
Controller Printed Circuit Board the BPR STATUS LED "FORWARD" will illuminate momentarily.
The actuator motor will not rotate in if the valve is less than one turn open.
Screen
3
Screen
rd
044
Touch SERVICE
MENU
BOOSTER PUMP
Rotation Direction
section 4 page 5 of 16
4
Screen
th
008
042
Touch FUNCTION
TEST
Aqua Matic 450-1800 Rev. A
5
Screen
TH
011
Touch as appropriate
to perform function
HIGH PRESSURE PUMP
Rotation Direction

Hide quick links: