Three Phase Power Supplied to the Aqua Matic System
Step Down Transformer Primary and Secondary
(inside the System Control Box)
Wiring and Voltages
Three Phase Aqua Matic System Voltage
from 200 VAC to 208 VAC
110 VAC
TO
115 VAC
SECONDAR
Three Phase Aqua Matic System Voltage
from 220 VAC to 240 VAC
110 VAC
TO
120 VAC
SECONDAR
Three Phase Aqua Matic System Voltage
from 380 VAC to 480 VAC
95 VAC
TO
120 VAC
SECONDAR
X3
H1
H2
X2
XF
H3
X1
H4
PRIMARY
X3
H1
H2
X2
XF
H3
X1
H4
PRIMARY
X3
H1
H2
X2
XF
H3
X1
H4
PRIMARY
section 9 page 29 of 36
Aqua Matic 450-1800 Rev. A
200 VAC
TO
208 VAC
220 VAC
TO
240 VAC
380 VAC
TO
480 VAC