It is preferable to mount the R.O. Membrane Vessel Assembly in a horizontal position. It is mounted either to the
floor, the wall, or over head. If mounting horizontally to a wall (vertical surface) The first R.O. Membrane Vessel
is mounted at the bottom and the second R.O. Membrane Vessel is mounted at the top. This allows air to be
displaced with feed water.
Note regarding Vertical Mounting of a Single R.O. Membrane Vessel Assembly: When Vertically mounting the
single R.O. Membrane Pressure Vessel Assembly always position the Inlet at the bottom and the Outlet at the
top. This allows air to be displaced with feed water.
Note regarding Vertical Mounting of a double R.O. Membrane Vessel Assembly: When Vertically Mounting the
double R.O. Membrane Pressure Vessel Assembly always position the Inlet of the first R.O. Membrane Pressure
Vessel at the bottom. By default, the Outlet of the second R.O. Membrane Pressure Vessel will also be at the
bottom. Vertically mounting a double R.O. Membrane Pressure Vessel Assembly will cause air to become
trapped in the second vessel. When the system pressurizes this air will eventually pass through the R.O.
Membrane Element and into the product water. Product water flow fluctuations will occur until all of the air
passes through.
With the supplied hardware attach the R.O. Membrane Vessel Assembly in line between the Outlet of the High
Pressure Pump and the Control Panel. Two High Pressure Hoses are supplied for attachment of the R.O.
Membrane Vessel Assembly to the High Pressure Pump and the Automation Control Panel. Each of these High
Pressure Hoses are 6 Feet long (1829mm). Plan accordingly so that these supplied High Pressure Hoses will
reach. Longer High Pressure Hoses can be ordered from Sea Recovery. DO NOT USE THIRD PARTY HIGH
PRESSURE HOSES. Use of 3rd party, non Sea Recovery supplied, high pressure hoses will void warranty of
those components that they connect to as well as any item damaged as a result of third party high pressure hose
failure.
20. The Rinse Clean Outlet Valve [55] is mounted below water level after the System Brine
Discharge Tee [34] located at the Automation Control Panel and before the Brine
Discharge Connector [35 or 36].
21. Brine Discharge Connector [35] or Multi Media Filter Waste "T" [36]
Attach the supplied Brine Discharge Connector [35] to the over board thru-hull connector [37].
or
if the Multi Media Filter [12] is installed then attach the supplied Multi Media Filter Waste "T"
[36] to the over board thru-hull connector [37].
22. The Fresh Water Flush Carbon Filter [51], with attached Fresh Water Flush 2-Way
Solenoid Valve [49] and Fresh Water Flush Check Valve [50] is mounted to a flat
vertical surface in an accessible location for filter element changing. Choose a location
between the Automatic Fresh Water Flush Check Valve [52] and a pressurized line from
the boat's fresh water pressure system [48].
section 2 page 45 of 56
Aqua Matic 450-1800 Rev. A
Brine Discharge
Connector
Multi Media
Filter Waste "T"
Fresh Water Flush
Carbon Filter, Check Valve
& 2-Way Solenoid Valve