11. Allow sufficient space after the Plankton Filter [11] Outlet for the Inline Vacuum/Pressure
Gauge [13], if used. If the Multi Media Filter is installed this Inline Vacuum/Pressure Gauge
[13] is not required as the Multi Media Filter includes inlet and outlet pressure gauges.
12. Prefilter. The 10 inch Dual Prefilters [15 & 16] and the Commercial Prefilter [14] serve
the same function. Use either the 10 inch Dual Prefilters or the Commercial Prefilter.
Do not use both. Using both is redundant and will lead to line pressure loss.
The Dual Prefilters [15 & 16] are mounted to a flat vertical surface. Allow minimum 4
inches (10 cm) below the bowl, and allow accessibility to the Filters for element removal
and maintenance.
or (either install the Dual Prefilters or Commercial Prefilter. Installing both is
redundant and will lead to line pressure loss).
The no-charge optional Commercial Prefilter [14] replaces the 10 inch Dual Prefilters [15 & 16].
The Commercial Prefilter is mounted to a flat horizontal surface using the supplied screws.
Maintain an orientation and accessibility that allows the operator access to remove the filter
element for maintenance. Allow minimum 12 inches above the top of the housing for filter element
removal. Mount the Commercial Prefilter in close proximity to the outlet of the Booster Pump and
the System frame. The commercial prefilter is plumbed as per the raised arrow and Inlet & Outlet
letters molded into the filter housing. The correct water flow enters the outer surface of the filter
element and migrates to the center core.
REFER TO THE ILLUSTRATION ON PAGE 42 OF THIS SECTION.
13. Allow sufficient space after the Commercial Prefilter [14] for the Inline Vacuum/Pressure
Gauge [17], if used.
14. If the Oil Water Separator will be installed and if the optional Differential Pressure
Transducer [19] will be installed, Place the Inline Pressure Pick Up T [18], for connection
to the Differential Pressure Transducer [19], after the Commercial Prefilter [14]. See
additional information regarding the Differential Pressure Transducer [19] on the
following page.
section 2 page 40 of 56
Inline Vacuum /
Pressure Gauge
Dual 10 Inch Prefilter
Commercial
Prefilter
Inline Vacuum /
Pressure Gauge
or
Pressure
Pick Up T