Aqua Matic 450-1800 Rev. A
14. Pressure Differential Transducer [19].
The optional Pressure Differential Transducer [19] threads into the center port of the Low Pressure Transducer
Manifold.
CAUTION: Take care to NOT cross the fine female threads in the manifold.
Thread in clockwise finger tight. Using a wrench tighten an additional 45 degrees.
DO NOT OVER TIGHTEN.
OVER TIGHTENING WILL STRIP THE MANIFOLD FEMALE THREADS.
Using the supplied 1/4 inch O.D. tubing connect the center Pressure Differential Transducer Tube Fitting to the
T-Connector Pressure Pick-Up [18] or to the Pressure Pick Up port of the respective Prefiltration component.
Refer to the various Piping and Interconnect Diagrams Illustrated in the prior pages of this Section.
Optional Pressure
Low Pressure
Differential
Transducer #1
Transducer #3
Optional Differential Pressure Transducer #3 [19]
Low Pressure
Transducer #2
Optional
Differential Pressure
Transducer #3 [19]
Low Pressure
Transducer #1 [10]
Note: Refer to appropriate Piping and Interconnect Diagram
for Tubing Connection to Manifold.
section 2 page 32 of 56
Electrical Box [57]
Remove Plug and
Insert Cable Through
Available Port
Low Pressure Transducer #2 [23]
Low Pressure Chassis Plate
Insert 1/4" OD Black Nylon Tubing
Through Connector
1/4" OD Black Nylon Tubing
to T-Connector Pressure Pick-up [18]
or appropriate Pressure Pick-up point
on individual Prefiltration Component
Strain RElief
PG 16