Sea Recovery SRC Aqua Matic 450-1 Owner's Manual

Sea Recovery SRC Aqua Matic 450-1 Owner's Manual

Reverse osmosis desalination system
Hide thumbs Also See for SRC Aqua Matic 450-1:
Table of Contents

Advertisement

Quick Links

Aqua Matic Modular 450-1800
Owner's Manual
Initial Release - 1 December 2008
FOR DECEMBER 2008 MODELS
SRC
Aqua Matic
SRC
Aqua Matic
SRC
Aqua Matic
Manual PN B651140002 | Revision: 0 / /1
450-1
SRC
Aqua Matic
700-1
SRC
Aqua Matic
900-1
SRC
Aqua Matic
900-2
1400-2
1800-2

Advertisement

Table of Contents
loading

Summary of Contents for Sea Recovery SRC Aqua Matic 450-1

  • Page 1 Aqua Matic Modular 450-1800 Owner’s Manual Initial Release - 1 December 2008 FOR DECEMBER 2008 MODELS Aqua Matic 450-1 Aqua Matic 900-2 Aqua Matic 700-1 Aqua Matic 1400-2 Aqua Matic 900-1 Aqua Matic 1800-2 Manual PN B651140002 | Revision: 0 / /1...
  • Page 3 Aqua Matic Modular 450-1800 Owner’s Manual...
  • Page 5 Aqua Matic Modular 450-1800 PREFACE Thank you for your purchase of a Sea Recovery Aqua Matic Troubleshooting and repair method results can vary Reverse Osmosis Desalination System. This manual contains depending on the information that is displayed at the SYSTEM instructions for the installation, operation, maintenance, INFORMATION screen.
  • Page 6 Certain aspects of the Sea Recovery Reverse Osmosis included within this manual, such as text, graphics, logos, Desalination System are protected by U.S. and International and images, is the property of Sea Recovery Corporation and Patent Laws. protected by U.S. and international copyright laws.
  • Page 7 Aqua Matic Modular 450-1800 REVISION HISTORY Rev. Date Affected Pages Description Ø 1 December 2008 Initial Release of the 2008 Models. 9/23/09 Pg.4-11 & FoldOut Revised Electrical Diagrams 11/18/09 General Re-formatting 11/23/09 Pg. 5-2 Multi Media Installation Instructions revision 6/23/10 Section 10 Updated Parts / Added NMEA kit 6/23/10...
  • Page 8: Table Of Contents

    Aqua Matic Modular 450-1800 TABLE OF CONTENTS INTRODUCTION PURPOSE SAFETY IN GENERAL USING THIS MANUAL TERM USED REFERENCES SAFETY NOTES GRAPHICS GLOSSARY SYSTEM DESCRIPTION MODELS SPECIFICATIONS COMPLIANCE WARRANTY REGISTRATION PACKING LIST COMPONENT DIMENSIONS DAILY SYSTEM READING CHEMICAL SAFETY 2.10 TEMPERATURE & PRESSURE EFFECTS PRE-INSTALLATION NOTES PRECAUTIONS SPECIAL CONSIDERATIONS...
  • Page 9 Aqua Matic Modular 450-1800 INTERCONNECTING COMPONENTS WATER TANK REMOTE TOUCH SCREEN ELECTRICAL CONNECTIONS LAND FEED WATER PICK-UP UV STERILIZER INSTALLATION COMMISSIONING CHECK INSTALLATION CHECK R.O. MEMBRANE 6.3. SETUP CONTROLLER CHECK SYSTEM MANUALLY OPERATION NOTES INITIAL STARTUP 6.6.1. POSITION SYSTEM VALVES 6.6.2.
  • Page 10 Aqua Matic Modular 450-1800 EXPLODED PARTS VIEW 10-1 10.1. WHEN ORDERING 10-1 10.3 AVAILABLE TUBES AND FITTINGS 10-2 10.4 INSTALLATION KIT B001990001 10-5 10.5 MAJOR PARTS 10-6 SEA STRAINER ASSY 3/4-B B006080002 10-6 BOOSTER PUMP ASSY N200 50/60/1 B016120001 10-7 BOOSTER PUMP ASSY N200 50/60/3 B016120002 10-8 BOOSTER PUMP HEAD N200 1221515772...
  • Page 11: Introduction

    Aqua Matic Modular 450-1800 Section 1 - INTRODUCTION...
  • Page 13: Glossary

    INTRODUCTION SAFETY NOTES PURPOSE Safety issues that require users attention are highlight This manual is intended for Sea Recovery’s system through out this manual as follows. technicians, technical support, and training personnel. This manual contains technical information & instructions WARNING: A Warning note provides...
  • Page 14 Aqua Matic Modular 450-1800 In addition to inferior product water quality, low brine SPIRAL-WOUND MEMBRANE flows can increase the precipitation of sparingly soluble The spiral-wound membrane consists of multiple salts which will foul the R.O. membrane element surface membrane envelopes each formed by enclosing a (concentration polarization).
  • Page 15 Aqua Matic Modular 450-1800 Section 2 - SYSTEM DESCRIPTION...
  • Page 17: System Description

    Sea Recovery Warranty. applications to customers all around the world. Since then Sea Recovery has become one of the top Refer to Page 2-11 for Limited Warranty. leaders in advanced water desalination systems for leisure marine applications.
  • Page 18 ( +-15% at 850 psig / 56 BAR, 77°F / 25°C & 35,000 PPM TDS Feed Water Salinity ) Model Number per 1 hour of operation: per 24 hours of operation: U.S. Gallons / Liters U.S. Gallons / Liters SRC Aqua Matic 450-1 1703 SRC Aqua Matic 700-1 2650 SRC Aqua Matic 900-1 3407...
  • Page 19 Aqua Matic Modular 450-1800 EXTERNAL INSTALLATION WATER CONNECTIONS: Pipe sizes to be supplied by the installer for connection of the Sea Recovery supplied components Aqua Matic Feed Inlet: 3/4 in. (19 mm) MNPT Male National Pipe Thread U.S. Standard Brine Discharge 3/4 in.
  • Page 20 Aqua Matic Modular 450-1800 RECOMMENDED CIRCUIT BREAKER SUPPLYING POWER TO SYSTEM AMPERAGE RATING: Operating Recommended AC Voltage Phase Circuit Breaker 110 - 115 VAC Single 50 Ampere 220 - 230 VAC Single 25 Ampere 220 VAC Three 15 Ampere 380 VAC Three 10 Ampere 460 VAC...
  • Page 21 Due to wide variety of specifications used in the products ABS has evaluated for Type Approval, it is part of our contract that; whether the standard is an ABS Rule or a non-ABS Rule, the Client has full responsibility for continued compliance with the standard. SEA RECOVERY CORP. Model Name(s): Aqua Matic Presented to: SEA RECOVERY CORP.
  • Page 22 Certificate Number: 06-HS159834E-1-PDA International Standards: Government Authority: EUMED: Others: None. Model Certificate Model Certificate No Issue Date Expiry Date 06-HS159834E-1-PDA 23/NOV/2010 22/NOV/2015 ABS Programs ABS has used due diligence in the preparation of this certificate and it represents the information on the product in the ABS Records as of the date and time the certificate was printed.
  • Page 26 fitness for a particular purpose. Warranty Period starts from the date of original shipment by Sea Recovery, or with proof of purchase from the date of sale to the original retail purchaser: 1.
  • Page 27 Aqua Matic Modular 450-1800 Some of the damages that may not be covered by the warranty include: Use of non-authorized or misuse of authorized chemicals for storage will void any warranty. Rust fouling of the R.O. Membrane Element is not covered under warranty.
  • Page 28 Aqua Matic Modular 450-1800 Installation Kit B001140003 ITEM PART NO DESCRIPTION 061100043000 WASHER FLAT OS 1/4”SS 12.00 EACH 061172143016 SC HEX “A” 1/4 X 1 SS 12.00 EACH 05181432AA HOSE CLAMP 1/2” 4.00 EACH 05181434AA HOSE CLAMP 3/4” SS 22.00 EACH 061170628016 SC PHIL PAN “A”...
  • Page 29 Aqua Matic Modular 450-1800 OPTIONAL ACCESSORIES Page 2-14...
  • Page 30 Aqua Matic Modular 450-1800 MODULAR UNIT DIMENSIONS 7" / 178 mm 17" / 432 mm 11" / 7" / 279 mm 178 mm 17" / 483 mm 20" / 508 mm Control Panel - Front 10.79 20.77 9.38 9.56 Page 2-15...
  • Page 31 Dual Post-filter Double R.O. Membrane Vessel Assembly a. 27 15/16” - 710mm: SRC Aqua Matic 450-1 & 900-2 b. 37 15/16” - 964mm: SRC Aqua Matic 700-1 & 1400-2 c. 46 15/16” - 1192mm: SRC Aqua Matic 900-1 & 1800-2...
  • Page 32 Aqua Matic Modular 450-1800 DAILY PERFORMANCE SHEET Sea Recovery Aqua Matic DAILY SYSTEM READINGS At the time of commissioning the NEW system, record the following information after one hour of continuous proper operation of the system. Retain this form in this Owner’s Manual for the owner and operator’s future reference. This information is valuable to the servicing technicians in providing technical support to the owner and future operators of the Aqua Matic.
  • Page 33 FLUSH EYES WITH WATER FOR 15 MINUTES & GET IMMEDIATE MEDICAL ATTENTION. THOROUGHLY WASH AFFECTED SKIN AFTER HANDLING PRODUCT. MEDICAL PERSONNEL FAMILIAR WITH Sea Recovery “SRC SC”, SYSTEM & MEMBRANE STORAGE CHEMICAL, ARE AVAILABLE 24 HOURS A DAY, 7 DAYS A WEEK, U.S.A. TOLL FREE MEDICAL EMERGENCY NUMBER: 1-800-228-5635.
  • Page 34 THOROUGHLY WASH AFFECTED SKIN AFTER HANDLING PRODUCT. CONTACT A PHYSICIAN IF IRRITATION PERSISTS. MEDICAL PERSONNEL FAMILIAR WITH Sea Recovery “SRC MCC2”, R.O. MEMBRANE ELEMENT ACID CLEANING CHEMICAL, ARE AVAILABLE 24 HOURS A DAY, 7 DAYS A WEEK, U.S.A. TOLL FREE MEDICAL EMERGENCY NUMBER: 1-800-228-5635.
  • Page 35: Temperature & Pressure Effects

    Aqua Matic Modular 450-1800 TEMPERATURE & PRESSURE EFFECTS Sea Recovery® TEMPERATURE EFFECT COMPARISON CHART (At 820 psi & 35,000 ppm feedwater TDS conditions) The Temperature Effect Chart on this page illustrates the loss or gain of productivity across the R.O. Membrane.
  • Page 36 (Do not use this chart for brackish water systems & applications) As the seawater temperature increases, the Sea Recovery system pressure must be adjusted so that the system achieves no greater than 100% of rated product water flow. Product water flow greater than 100% of rated capacity causes premature fouling of the R.O.
  • Page 37 Aqua Matic Modular 450-1800 This page is intentionally left blank. Page 2-22...
  • Page 38 Aqua Matic Modular 450-1800 Section 3 - PRE-INSTALLATION NOTES...
  • Page 40: Pre-Installation Notes

    Recovery System to intake Feed Water Piping and Plumbing Systems from any chemical, not approved in Water Suction and Pressure Lines writing by Sea Recovery or any of the following chemicals: Thru-Hull Fitting below and above water level Hydrogen peroxide...
  • Page 41: Distance Between Components

    The inlet Thru Hull Fitting must be minimum 3/4 in. The Electrical Control Touch Panel must be accessible for (19 mm) and dedicated to only the Sea Recovery operation and monitoring of the system. system. It is important that the installer utilizes a...
  • Page 42: Piping And Interconnect Diagrams

    A blockage or closed valve will cause damage configurations. to the System. Connection of the Sea Recovery Product Water Line to the boat’s UNPRESSURIZED Potable Note: Symbol Used in this Section. Water Storage Tank requires a 1/2 in. (12.7 mm)
  • Page 43 Aqua Matic Modular 450-1800 System P&ID-Dual Prefilters Page 3-4...
  • Page 44 Aqua Matic Modular 450-1800 System P&ID-Commercial Prefilters Page 3-5...
  • Page 45 Aqua Matic Modular 450-1800 Page 3-6...
  • Page 46 Aqua Matic Modular 450-1800 Page 3-7...
  • Page 47 Aqua Matic Modular 450-1800 Page 3-8...
  • Page 48 Aqua Matic Modular 450-1800 Page 3-9...
  • Page 49 Aqua Matic Modular 450-1800 Page 3-10...
  • Page 50 Aqua Matic Modular 450-1800 Page 3-11...
  • Page 51 Aqua Matic Modular 450-1800 Page 3-12...
  • Page 52 Aqua Matic Modular 450-1800 Page 3-13...
  • Page 53 Aqua Matic Modular 450-1800 Page 3-14...
  • Page 54 Aqua Matic Modular 450-1800 Page 3-15...
  • Page 55: Explanation Of Pressure Transducers

    Aqua Matic Modular 450-1800 EXPLANATION OF PRESSURE TRANSDUCERS The Optional Differential Pressure Transducer #4 (not Standard Transducers: The Illustration below shown) measures the pressure between two Prefiltration shows the Standard Pressure Transducers included components. The difference of the pressure into and out with each System.
  • Page 56: Membrane Element Notes

    R.O. membrane elements are not installed and you Non Sea Recovery, components will void any and all wish to install them at this time contact Sea Recovery Sea Recovery Warranty. We only wish to help you enjoy the luxury of owning a Sea Recovery R.O. System. Treat and supply us with your original Purchase Order Number, Sea Recovery’s Invoice Number, and this...
  • Page 57 Do not use third party prefilter elements, enter the thru-hull fitting, it will cause the use only Sea Recovery prefilter elements. system to continually shut down due to Third party prefilter elements do not loss of feed water.
  • Page 58 first R.O. Membrane very costly damage to the High Pressure Element and Vessel. The Sea Recovery R.O. Pump as well as premature fouling of the System will have either one or two R.O. Membrane R.O.
  • Page 59 Aqua Matic Modular 450-1800 Brine Discharge T-Connector collects the brine the feed water section. Fresh water flushing of the discharge water and unpotable product water. system helps to minimize this odor. Brine Discharge Connector attaches to the over pH Neutralizer Filter The pH value of pure water board thru-hull fitting for connecting the brine is pH7 which is regarded as neutral.
  • Page 60 Aqua Matic Modular 450-1800 FRESH WATER FLUSH SECTION ELECTRONIC SECTION The Fresh Water Flush Section includes a Carbon The Electronic Section measures water quality, controls Filter and an Automatic Motor Actuated Ball Valve that the direction of Product Water flow, Starts and Stops the automatically flushes the system with fresh water.
  • Page 61 Aqua Matic Modular 450-1800 When the Fresh Water Tank is several inches below the full mark the switch is Closed. As water rises and reaches the top of the full mark the switch Opens. This informs the System Control Logic that the Fresh Water Tank is full.
  • Page 62 Aqua Matic Modular 450-1800 Section 4 - ELECTRICAL INFORMATION...
  • Page 64: Electrical Information

    Aqua Matic Modular 450-1800 ELECTRICAL INFORMATION of a second after which the current drops to normal running load. Then the High Pressure Pump Electric ELECTRICAL REQUIREMENTS AND Motor starts and surges to “locked Rotor” amperage for INFORMATION a fraction of a second after which the current drops to Following are general electrical requirements and normal running load.
  • Page 65: Electrical Motor Specifications

    Aqua Matic Modular 450-1800 4.2. ELECTRICAL MOTOR SPECIFICATIONS (H.P. = Horse Power; RPM = Revolutions Per Minute; FLA = Full Load Amperes; LRA = Locked Rotor Amperes @ Start Up) ALTERNATING CURRENT SYSTEMS: Single Phase Alternating Current: High Pressure Pump Motor Booster Pump Motor 2850 2850...
  • Page 66: Recommended Power Wire Size

    Aqua Matic Modular 450-1800 4.4. RECOMMENDED POWER WIRE SIZE Recommended power wire size to Aqua Matic system and pump motors: RECOMMENDED POWER WIRE SIZE TO AQUA MATIC SYSTEM: Operating Maximum Recommended Minimum Wire Size for Length of run Voltage Phase Load 10 Ft / 3 meter 25 Ft / 8 meter...
  • Page 67: Wire Insertion To Terminal Strips

    Aqua Matic Modular 450-1800 4.5. WIRE INSERTION TO TERMINAL STRIPS 4.6. WIRE SIZE REFERENCES Wire Size Cross Reference American Wire Gauge (AWG) vs. Metric Wire Sizes Diameter Square Diameter Square Inch Inch (In2) Millimeters Millimeters (mm2) 0.46 0.1661 11.684 107.1649 0.4096 0.1317 10.4038...
  • Page 68 Aqua Matic Modular 450-1800 American Wire Gauge Metric Wire Gauge Metric Wire dia inch sq. inch dia mm sq mm Size mm2 0.46 0.1661 11.684 107.1649 0.4096 0.1317 10.4038 84.9683 0.3648 0.1045 9.2659 67.398 0.3249 0.0829 8.2525 53.4609 0.2893 0.0657 7.3482 42.3871 0.2576...
  • Page 69: Modular Model Electrical Information

    Aqua Matic Modular 450-1800 4.7. MODULAR MODEL ELECTRICAL INFORMATION WARNING: ELECTRICAL SHOCK HAZARD. A Volt / Ohm Meter will be necessary. The following installation procedures expose the installer to High Voltage and electrical shock hazard. Only attempt this if you are a qualified electrician and only if surrounding conditions are safe.
  • Page 70 2. OPTIONAL THERMOSTAT IS PROVIDED WHEN SPECIFIED. 3. MULTIPLE CAPACITORS ARE CONNECTED IN PARALLEL UNLESS OTHERWISE SPECIFIED. 4. LEAD COLORS ARE OPTIONAL. LEADS MUST ALWAYS BE NUMBERED AS SHOWN. Sea Recovery BOOSTER PUMP ELECTRIC MOTOR WINDINGS DIAGRAM CD0093 SINGLE PHASE...
  • Page 71 Electrical Motor Wiring-Three Phase ELECTRIC MOTOR WINDING / WIRING DIAGRAMS THREE PHASE, 50/60 Hz, 220-230 VAC, // 380-460 VAC NOTES Sea Recovery 1. INTERCHANGE ANY TWO LINE LEADS TO REVERSE ROTATION. BOOSTER PUMP 2. OPTIONAL THERMOSTAT IS PROVIDED WHEN SPECIFIED.
  • Page 72 Aqua Matic Modular 450-1800 Three Phase Transformer Wiring Page 4-9...
  • Page 73 Aqua Matic Modular 450-1800 Electrical Chassis Single Phase ITEM NO. PART NUMBER DESCRIPTION QTY. 313106038F HP PUMP CONTACTOR 31318301DX EMI FILTER B604170001 POWER SUPPLY ASSY B604170000 DIN RAIL ASSY Three Phase ITEM NO. PART NUMBER DESCRIPTION QTY. 313106038F HP PUMP CONTACTOR 3131131500 ELEC TRANSFORMER 480/120 BUCK...
  • Page 74: Modular Model Wiring Diagrams

    Aqua Matic Modular 450-1800 MODULAR MODEL WIRING DIAGRAMS WARNING: ELECTRICAL SHOCK HAZARD. A Volt / Ohm Meter will be necessary. The following installation procedures expose the installer to High Voltage and electrical shock hazard. Only attempt this if you are a qualified electrician and only if surrounding conditions are safe.
  • Page 75 Aqua Matic Modular 450-1800 Soft Start Wiring Diagram B596800006 Single Phase Wiring Connections: FUSES (2A X 2) WHT/BLK WHT/BLK WHT/RED WHT/RED L1-BLK L1-BLK L2 (N)-RED L2 (N)RED T1-BLK T1-BLK T2-RED T2 (N)-RED T1-BLK T1-BLK T2-WHT T2 (N)-RED G-GRN Note: Refer to the wiring diagram for details. T1-BLK T1-BLK T1-B/W...
  • Page 76 Aqua Matic Modular 450-1800 3 Phase Wiring Connections: L1-BLK L2-RED L3-BLU T1-BLK T2-RED T3-BLU HP Pump Soft Contactor T1-BLK T1-B/W Start T2-WHT T2-W/B T3-BLU T3-BLU G-GRN G-GRN Note: Refer to the wiring diagram for details. If the Motor Soft Start is not already installed, follow these instructions to install it: 1.
  • Page 77 Aqua Matic Modular 450-1800 This page is intentionally left balnk. Page 4-14...
  • Page 78 Aqua Matic Modular 450-1800 Section 5 - INSTALLATION REQUIREMENTS...
  • Page 80: Installation Requirements

    The optional Rinse Clean Inlet Valve with attached Sea Recovery warranty. Grind flat or use appropriate Rinse Clean Outlet Valve is mounted below water shims on uneven surfaces to ensure that mounting of the level between the outlet of the Sea Strainer and system components does not cause bending or warping.
  • Page 81 Aqua Matic Modular 450-1800 The optional Plankton Filter (single or double Allow sufficient space after the Plankton Filter housing version) is mounted to a flat vertical Outlet for the Inline Vacuum/Pressure Gauge, if surface using the supplied screws. Allow used. If the Multi Media Filter is installed this Inline minimum 4 in.
  • Page 82 Aqua Matic Modular 450-1800 Figure 5b: Follow the labeling - NOT the molded arrows and lettering Page 5-3...
  • Page 83 Aqua Matic Modular 450-1800 However, the Oil/Water Separator is UV Sterilizer Installation. The Ultra Violet Sterilizer plumbed opposite of (backwards from) the should be mounted on a flat horizontal or vertical Commercial Prefilter. The standard filter wall. Refer to Section 5.8 for installation details. housings have raised arrows and lettering The Fresh Water Flush Carbon Filter, with attached molded indicating correct flow for the...
  • Page 84: Interconnecting Components

    Aqua Matic Modular 450-1800 **If water lines are pulled tight causing them to 1/4 in. (6.35 mm) OD nylon tubing is supplied with bend at the fitting they will leak, allow air to enter, applicable components for connecting Pressure fail prematurely, and or break the fitting that they Pick Up points to the Low Pressure Transducers.
  • Page 85: Water Tank

    Aqua Matic Modular 450-1800 WATER TANK If operation of the System is desired when the Fresh Water Tank Switch signals the System Control Logic CUSTOMER SUPPLIED FRESH WATER TANK, HIGH AND that the Fresh Water Tank is full then the System may LOW LEVEL SWITCHES, AND ALARM be operated in the Manual mode.
  • Page 86 Aqua Matic Modular 450-1800 Example of Water intake from a Deep Well Example of Water intake from a Feed Source Page 5-7...
  • Page 87: Uv Sterilizer Installation

    Aqua Matic Modular 450-1800 UV STERILIZER INSTALLATION Wrap ¼ in (6.35 mm) wide PTFE tape 2 to 3 turns counter-clockwise around the male threads of the The SP Series UV unit is shipped with the UV lamp, quartz ¼ in (6.35 mm) fitting. sleeve, fittings, and O-rings and need to be assembled Do not wrap tape around the first thread.
  • Page 88 Aqua Matic Modular 450-1800 Lubricate the tips of the quartz sleeve with clean NOTE! To remove water and insert new O-ring. Ensure the O-ring tube from fitting, first has all-round contact with the cylinder pass-thru. remove the C-clamp then push fitting Tighten the compression nut while making sure sleeve down.
  • Page 89 Aqua Matic Modular 450-1800 CAUTION! Standard flow rate are based CAUTION! Rapid successive cycling of the power to the ballast can cause on water temperature 35ºF to 100ºF premature failure of the unit. (2ºC to 38ºC). If the inlet water temperature exceeds 100ºF (38ºC), please contact your local CSR.
  • Page 90 Aqua Matic Modular 450-1800 Section 6 - COMMISSIONING...
  • Page 92: Commissioning

    6.3. SETUP CONTROLLER Improperly connected or loose connected lines The controller is set by Sea Recovery prior to shipping resulting in leaks causing damage is the liability of based on the features and optional equipment that the installer and the operator, and is not covered by shipped with the System at the time of ordering.
  • Page 93: Check System Manually

    Aqua Matic Modular 450-1800 A. FEATURES PROGRAMMABLE BY OPERATOR d) PRESSURE Manually control the system pressure by The following is an explanation of features that are increasing or decreasing the setpoint of the programmable by the operator. It is required that each back pressure regulator.
  • Page 94: Operation Notes

    Separator filter element • BPR OUT: Back Pressure Regulator f ) R.O. Membrane(s) check for Sea Recovery Motor Actuator will rotate counter clock Serial Number and Date on the label attached wise momentarily. The actuator motor to each pressure vessel.
  • Page 95: Initial Startup

    Aqua Matic Modular 450-1800 Product Water Flow Meter will register product MULTI MEDIA FILTER BACKWASH AND RINSE: water flow, as operating pressure exceeds the If the System is equipped with a Multi Media Filter it osmotic pressure of the feed water. Product Water must be back washed and rinsed.
  • Page 96: Apply Power To The System

    After the control logic has initiated itself, the B. MANUAL MODE default screen will appear indicating that the The Manual Mode is intended for Sea Recovery System is ready to Start (fig. 6a). technicians for setup and configuration purposes.
  • Page 97: Log System Readings

    Aqua Matic Modular 450-1800 On the Salinity Level screen, adjust the salinity 6.6.5. SHUTDOWN THE SYSTEM to desired level (188 to 370 PPM) then touch the A. AUTOMATIC MODE SETUP button. From the default screen, touch the STOP button. On the next screen, touch the Manual Mode button. If the Automatic Fresh Water Flush option is not On the next screen, touch the Booster Pump installed the shut down sequence is complete:...
  • Page 98 Aqua Matic Modular 450-1800 is purged, although the system is producing “Product after the sequence listed above; the Fresh Water Flush Water”, the Product Water may not be “Potable” for up to Solenoid Valve will energize for 7 to 15 minutes, allowing 30 minutes.
  • Page 99 Aqua Matic Modular 450-1800 Sea Recovery Aqua Matic NEW SYSTEM INITIAL READINGS At the time of commissioning the NEW system, record the following information after one hour of continuous proper operation of the system. Retain this form in this Owner’s Manual for the owner and operator’s future reference. This information is valuable to the servicing technicians in providing technical support to the owner and future operators of the Aqua Matic.
  • Page 100 Aqua Matic Modular 450-1800 Section 7 - OPERATION...
  • Page 102: Operation

    Aqua Matic Modular 450-1800 OPERATION The System may be manually stopped, or it may be programmed to stop at a given time or given NOTE - Automated Operational volume of Product Water production. Sequence: During operation, touching STOP at any time immediately stops all If the STOP is touched the System will immediately functions of the System.
  • Page 103 SHORT STORAGE: If the System is not equipped with the care and protection, is the liability of the operator, and is Automatic Fresh Water Flush option, perform a manual not covered by the Sea Recovery warranty. fresh water flush. Refer to Section 7.3 for Short Term Storage Procedures.
  • Page 104: Daily Operation

    System if left closed during starting and/ B. MANUAL MODE or operation of the system. The resulting The Manual Mode is intended for Sea Recovery damage to the system is attributed to technicians for setup and configuration purposes. improper installation, is the liability of the...
  • Page 105: Log System Readings

    Product Water have not yet B. MANUAL MODE decreased to acceptable level. This mode of operation is intended for Sea Recovery technicians for setup and configuration purposes. Although the system is producing “Product Water”, the Product Water may not be “Potable”...
  • Page 106 Closed Loop” refer to page 7-6, figure 7b and proceed Sea Recovery R.O. membrane element. as follows: Damage to the Sea Recovery System or components within the System are not Configure the Suction line for a Closed Loop covered by the Sea Recovery Warranty.
  • Page 107 Aqua Matic Modular 450-1800 Figure 7a: ONCE THROUGH RINSE This is used to rinse the system with fresh water, to winterize the system, and also to discharge the content if the cleaning solution bucket. Figure 7b: RECIRCULATING CLOSE LOOP This is used to circulate cleaning or storage solution through the system. Note: The above illustrations show representations of components and may not show actual or all components.
  • Page 108 Aqua Matic Modular 450-1800 Figure 7c: Simplified Aqua Matic Once Through Rinse Figure 7d: Simplified Aqua Matic Re-Circulating Loop Page 7-7...
  • Page 109: Short-Term Shutdown

    NOTE: If the system is exposed to a) 20 gallons (75.7 liters) of potable water. freezing temperatures, DO NOT activate b) Sea Recovery Storage Chemical SRC SC the Automatic Fresh Water Flush. c) 2 Gallons (7.5 liters) of food grade...
  • Page 110: Winterizing Procedure

    Aqua Matic Modular 450-1800 Start the System in the MANUAL MODE R.O. MEMBRANE CLEANING Do not arbitrarily clean the R.O. membrane in a NEW Operation of the System will deplete the Fresh system. The R.O. membrane element in a NEW System Water in the bucket.
  • Page 111 R.O. membrane at the same time. Mix the cleaning element may be returned to Sea Recovery or chemicals separately and use them to one of Sea Recovery’s many Service Dealers separately. Use only Sea Recovery for professional chemical cleaning.
  • Page 112 Once again, fill the container with 10 gallons (37.8 liters) clean, fresh water. Add to the 10 gallons (37.8 liters) of fresh water 1.5 lbs. (0.68 kg) of Sea Recovery Membrane Cleaning Compound MCC 1, MCC 2 or MCC 3. Thoroughly mix the solution until the cleaning compound has dissolved.
  • Page 113 Aqua Matic Modular 450-1800 Sea Recovery Aqua Matic DAILY SYSTEM READINGS Make Copies of this form and fill one in each time the System is operated. Record the following information after one hour of continuous proper operation of the system, or just prior to stopping the System.
  • Page 114 Aqua Matic Modular 450-1800 Section 8 - MAINTENANCE AND REPAIR...
  • Page 116: Maintenance And Repair

    Electromechanical and Mechanical Systems the Sea Recovery Warranty. Hydraulic and Liquid Pressure and Flow Systems Do not connect any water line to the Sea Recovery Piping and Plumbing Systems R.O. System that may contain any of the above listed Water Suction and Pressure Lines chemicals.
  • Page 117: Weekly Quick Check

    WEEKLY QUICK CHECK liability and responsibility of both the Marine Dealer that The following steps ensure that potential problems are sold the component for use in the Sea Recovery System resolved preventing major repairs: as well as the Owner/Operator that purchased and...
  • Page 118 Booster Pump and High one Thru Hull fitting for other equipment Pressure Pump resulting in continual will cause the Sea Recovery System to system shut down due to low feed water draw air or cavitate leading to continual flow and pressure.
  • Page 119 Sea Recovery warranty. Plumb the Sea Recovery fail again.
  • Page 120 Aqua Matic Modular 450-1800 the capacitor will short out. Without the aid of b) Measure voltage at the motor during attempt a working capacitor the motor will “hum”, pull to start it. If voltage drops more than 10% starting current (locked rotor) amperage, not locate and correct the reason.
  • Page 121 Aqua Matic Modular 450-1800 Some Electric Motors supplied by Sea Recovery have through it. When the silica sand becomes packed permanently sealed and lubricated bearings. Others with suspended solids, as indicated by a loss of require lubrication from time to time. If your Electric pressure, it must then be back washed to waste.
  • Page 122 SUPPLIED PREFILTER ELEMENTS. The resulting failure of the system to remain in operation, and or damage to the Sea Recovery System caused by Third Party Prefilter damage the element rendering it useless. Change Elements is attributed to improper maintenance and the element after the first or second cleaning.
  • Page 123 O-Ring lubricant. internal parts. The Sea Recovery Prefilter will g) Insert the cleaned or new Sea Recovery stop any debris and protect the High Pressure Commercial Prefilter Pleated Cartridge Pump. Use caution when changing filter Element into the bowl.
  • Page 124 Any debris entering the Pump will high power, below or above the cause extensive and expensive damage to the specified voltage requirements internal parts. The Sea Recovery Prefilter will of the system. This is Not stop any debris and protect the High Pressure economically repairable.
  • Page 125 Any debris entering the from, and in between the Power Supply Pump will cause extensive and expensive damage to the and the electric motor. Correct wire size internal parts. The Sea Recovery Prefilter will stop any or any loose wires. Page 8-10...
  • Page 126 High Pressure Pump fails to properly function return it to each end of the Pressure Vessel. Sea Recovery, or to a Sea Recovery Authorized Dealer for c) Push inward on the End Plug [3 & 4] and return to Sea Recovery.
  • Page 127 Aqua Matic Modular 450-1800 diameter by 1 in. (2.5 cm) long. The outside A new Sea Recovery R.O. membrane element diameter surface of this product water tube is comes complete with a “U” cup Brine Seal a sealing surface, which isolates the Product #8 at one end of the Element.
  • Page 128 Aqua Matic Modular 450-1800 aligning the High Pressure Port and Product WARNING: Anytime the valve stem and Water Port to the respective holes in the High or Motor gear shaft is rotated separately Pressure Vessel. Continue pushing inward on from the other they must be replaced. the End Plug until its exposed end travels just If the coupler set screws have become past the Segment Ring Groove in the Pressure...
  • Page 129 Aqua Matic Modular 450-1800 CAUTION: DO NOT over tighten the Multi Media Filter Waste & Brine Discharge Tee: This 90 degree elbow fitting attaches to the over packing gland. Over tightening will cause premature wear and failure of the packing board thru-hull fitting for connecting the brine discharge hose.
  • Page 130 Aqua Matic Modular 450-1800 Figure 8e.: VALVE WITH PORT DESIGNATION “A” “P” “B” 8) With your mouth, blow into port “P”, air should expel from port “A” which is the PLUG REMOVE BY LOSENING SCREW “normally closed” or “good water” port. AT TOP AND “POPPING OFF”...
  • Page 131 Insert the new, Sea Recovery pH Neutralizing or damage to the Sea Recovery System caused by Third Cartridge into the bowl. Party Charcoal or Carbon Filter Elements is attributed to Screw the bowl on clockwise.
  • Page 132 Place the O-Ring back onto the bowl. Quartz Sleeve Cleaning: h) Insert the new, Sea Recovery Carbon Filter a) Remove the four screws on the ballast box Element into the bowl. and remove lid.
  • Page 133: Uv Sterilizer Maintenance

    Aqua Matic Modular 450-1800 UV STERILIZER MAINTENANCE Unit Maintenance Follow the preventative maintenance procedures to The exterior surfaces of the UV unit should be kept clean maximize the efficiency, reliable, and longevity of the UV and dry. In most cases it may be necessary to clean the Sterilizer.
  • Page 134 Aqua Matic Modular 450-1800 Checking for Leaks NOTE! Sea Recovery recommends a valve with a discharge orifice not to Visual inspect the UV unit exterior for signs of leakage. exceed ¼” (6mm). The cause of any leakage must be located and repaired.
  • Page 135 Aqua Matic Modular 450-1800 Periodic Maintenance Table The table below represents the recommended Periodic Maintenance (PM) for the SP Series UV Unit. Description Init. Daily Ann. Other Quartz Sleeve Cleaning Quartz Sleeve Replacement* Operating Condition Unit Cleaning Leak Inspection UV Lamp Inspection UV Lamp Replacement-SP-1 4,400 hrs UV Lamp Replacement-SP-2...
  • Page 136 Aqua Matic Modular 450-1800 Section 9 - TROUBLESHOOTING...
  • Page 138: Troubleshooting

    For each symptom, one or more causes are given. In turn, each cause has one or more From time to time, Sea Recovery may make changes to corresponding tests to help identify whether the cause the Control Logic.
  • Page 139: Troubleshooting Components

    High Pressure sensor failed to measure the one Thru Hull fitting for other equipment pressure. Check wiring. will cause the Sea Recovery System to Temperature Sensor (#) failed to measure the draw air or cavitate leading to continual temperature. Check wiring.
  • Page 140 Solution: Inspect the Inlet Thru-Hull Fitting and installation, is the liability of the installer, clean all manufacturing debris and casting slag and is not covered by the Sea Recovery from the fitting. warranty. Plumb the Sea Recovery System to the “bottom” of such feed...
  • Page 141 Aqua Matic Modular 450-1800 INLET CONNECTOR the System is in operation. If the Sea Strainer O-Ring is not properly seated air will enter the AS WELL AS ALL FITTINGS AND CONNECTIONS PRIOR TO feed line causing the System to loose pressure. THE INLET OF THE BOOSTER PUMP: Look for air bubbles moving through the Sea Problems and Symptoms appearing and caused by...
  • Page 142 Aqua Matic Modular 450-1800 T-CONNECTOR PRESSURE PICK-UP PLANKTON FILTER Booster Pump Outlet/Prefilter Inlet for line pressure This optional filter assembly contains a cleanable pick up to Low Pressure Transducer #1 between the ultra fine monel mesh screen. The mesh screen traps outlet of the Booster Pump and the inlet of the first suspended solids or biological growth such as plankton.
  • Page 143 This over size cartridge provides extended Do not use third party prefilter elements, life that greatly reduces maintenance and prefilter use only Sea Recovery prefilter elements. element replacement cost. As the cartridge filter element Third party prefilter elements do not becomes plugged up with debris pressure and flow drop...
  • Page 144 System will accept is 4.5 VDC. damage to the High Pressure Pump. The variation of voltage output from the Transducer is Damage to the Sea Recovery System converted to pressure value by the System Control Logic. caused by the use of third party, non...
  • Page 145 Aqua Matic Modular 450-1800 Problems and Symptoms appearing and caused by the The pressure readings at the Touch Pad are Oil/Water Separator: inaccurate. The minimum voltage output is below 0.5 VDC and or the maximum voltage The Feed Water Pressure into the Oil/Water output is above 5 VDC.
  • Page 146 Aqua Matic Modular 450-1800 Single Phase Motor or connection at the motor or within the power supply line, and “burnt” contacts on the motor The Single Phase (115 or 230 VAC) Electric Motor starter relay (contactor). “hums”, pulls starting current (locked rotor) amperage, does not rotate, and trips the supply Solutions: Check wiring size and connections power circuit breaker when attempting to operate...
  • Page 147 High Solution: Inspect seals and replace if necessary. Pressure Pump has lost Flow and or Pressure then return the High Pressure Pump to Sea Recovery Normal flow when not pressurized but flow drops for servicing.
  • Page 148 Brine Flow will decrease appropriately (by the increase in Product Water). The High Pressure Hose has been assembled with crimp fittings by Sea Recovery. The High Pressure Hose is NOT Solution: Replace the O-Ring if wear or damage repairable. Should a leak, damage, or failure develop is present.
  • Page 149 Aqua Matic Modular 450-1800 months, increases, quality decreases: seal is the “Brine O-Ring”. Should a leak develop between the End Plug and the inside wall of the As the Reverse Osmosis Membrane Element is Pressure Vessel remove the end plug and inspect exposed, operated or not, to Sea Water eventually the Brine O-Rings for wear or damage.
  • Page 150 Aqua Matic Modular 450-1800 base. Electrical troubleshooting may be performed to When the System Feed Water is lower than determine if it is damaged, functional, or non functional. normal in salinity and/or higher than normal in temperature the operating pressure will The Back Pressure Regulator Valve contains a seal that automatically decrease to not exceed the specified is serviceable.
  • Page 151 Aqua Matic Modular 450-1800 The Brine Flow Meter does not register the proper THRU HULL DISCHARGE FITTING** Brine Water Flow at the Touch Pad. The Discharge Thru-Hull Fitting should be installed above water level for discharge of the Brine Discharge Debris may be trapped within the flow meter body Water from the system.
  • Page 152 Aqua Matic Modular 450-1800 Solution: Check control logic setup. The 3-Way Product Water Diversion Solenoid Valve Refer to Section 6.8. is allowing Brine Discharge Water to mix with Potable Water. One of the following abnormalities is causing High Product Water Flow: Damage to the R.O. There is a blockage in the Brine Discharge line membrane element;...
  • Page 153 Product Water kPa) If the Fresh Water Flush cycle is unable to perform Line. Damage to the Sea Recovery due to insufficient Fresh Water flow and pressure replace System caused by the use of Non Sea...
  • Page 154 Aqua Matic Modular 450-1800 AUTOMATIC FRESH WATER FLUSH Fresh Water Flush Check Valve stops feed water from entering the potable water line. Includes a 2-Way Solenoid Valve, potable water Check Valve, Carbon Filter, and feed water Check Valve that Problems and Symptoms appearing and caused by the allow automated flushing of the System with Fresh Water.
  • Page 155: Electrical Troubleshooting

    Aqua Matic Modular 450-1800 CLEANING BUCKET** Solution: Delayed response to Touch commands is normal depending on the data being processed at This can be any non ferrous (non iron) container capable that instant by the System Logic Controller. of holding at least 10 U.S. Gallons (37.8 Liters) of water. This container is used during the R.O.
  • Page 156 Aqua Matic Modular 450-1800 REMOTE CONTROL TOUCH PANEL*** When installed and connected to the Main Printed Circuit Board, the Fresh Water Tank High Level Switch must be Refer to SYSTEM TOUCH SCREEN for connected as a N.C. (Normally Closed) 1PST (One Pole similar troubleshooting.
  • Page 157 Aqua Matic Modular 450-1800 e. Fresh Water Flush Relay 4 Customer Supplied Alarm The maximum allowable current consumption at the Automatic Fresh Water Flush Valve Motor customer’s supplied alarm is 1 Ampere at 12 VDC. Actuator g. Automatic Back Pressure Regulator Valve 5 12 VDC Power Supply Motor Actuator The 12 VDC Power Supply provides power to:...
  • Page 158 Aqua Matic Modular 450-1800 7 Step Down Transformer used in 3 phase systems only The Step Down Transformer is not required for single phase systems. It is only required for three phase systems. It accepts the high voltage operating power at its primary and steps the voltage down to 115 VAC out of the transformer’s secondary for primary input power to the 12 VDC Power Supply.
  • Page 159 Aqua Matic Modular 450-1800 Page 9-22...
  • Page 160 Aqua Matic Modular 450-1800 Section 10 - EXPLODED PARTS VIEW...
  • Page 161 This page is intentionally left blank.
  • Page 162: Exploded Parts View

    EXPLODED PARTS VIEW 10.1. WHEN ORDERING When ordering Parts or Accessories from your local Sea Recovery Dealer or from Sea Recovery direct, order to save time and to ensure that you receive the correct part provide the following information: System Model...
  • Page 163: Available Tubes And Fittings

    Aqua Matic Modular 450-1800 10.3 AVAILABLE TUBES AND FITTINGS PART NO DESCRIPTION PART NO. DESCRIPTION 1. CONNECTOR MALE 3. ELBOW 90 MALE 0204090669 1/4 inch tube x 1/8 inch mnpt 0204020669 1/4 inch tube x 1/8 inch mnpt 0204090869 1/4 inch tube x 1/4 inch mnpt 0204020869 1/4 inch tube x 1/4 inch mnpt 0204091669...
  • Page 164 Aqua Matic Modular 450-1800 AVAILABLE TUBE COMPRESSION FITTINGS CONTINUED PART NO. DESCRIPTION 6. RUN TEE MALE 0204170669 1/4 inch tube x 1/8 inch mnpt 0204170869 1/4 inch tube x 1/4 inch mnpt 0204171769 3/8 inch tube x 1/4 inch mnpt 0204171869 3/8 inch tube x 3/8 inch mnpt 0204172469...
  • Page 165 Aqua Matic Modular 450-1800 TUBE COMPRESSION FITTINGS REPLACEMENT PARTS ITEM DESCRIPTION PART NO. FOR 1/4" O.D. TUBE NUT/SPACER/GRAB & O-RING 1/4" 0204-1/469 TUBE 1/4 BLACK 0312121969 FOR 3/8" O.D. TUBE NUT/SPACER/GRAB & O-RING 3/8" 0204-3/869 TUBE 3/8 BLACK 0312123569 FOR 1/2" O.D. TUBE NUT/SPACE/GRAB &...
  • Page 166: Installation Kit B001990001

    Aqua Matic Modular 450-1800 10.4 INSTALLATION KIT B001990001 ITEM PART NO DESCRIPTION 0112652500 ADAP 1/2 MNPT X 1/2 BARB NYLON EACH 01126526DG ADAP 1/2 MPT X 3/4 BARB NYLON EACH 0112653700 ADAP 3/4 MPT X 3/4 BARB NYLON EACH 0204020869 ELB90 1/4 TUBE X 1/4 MPT PLAST EACH 0204021969...
  • Page 167: Major Parts

    Aqua Matic Modular 450-1800 10.5 MAJOR PARTS SEA STRAINER ASSY 3/4-B B006080002 ITEM PART NUMBER DESCRIPTION B006080002 SEA STRAINER ASSY 3/4-B (INCLUDES P/N 2-7) 0101073783 ELB90 .75 MNPT X .75 BARB PVC EACH 05181434AA HOSE CLAMP 3/4” SS EACH 0421051239 SEA STRAINER-3/4 BRONZE EACH 0421051239-1...
  • Page 168 B016080026 BOOSTER PUMP ASSY 1PH HP75 ITEM NO. QTY. PART NUMBER DESCRIPTION 1205514772 BOOSTER PUMP HEAD HP75 W-4.75 IN IMPELLER 1519081110 MOTOR .50 HP 110-230-50-60-1PH 1920023632 STRAIN RELIEF 90 CG90-6250 0112653700 ADAP .75 MPT X.75 BARB NYLON 01120737DG ELB90 .75 MPT X .75 BARB NYLON 061172143016 SCREX,HEX A,.25x1.00,SS 063200066000...
  • Page 169 RECOMMENDED SPARES: QTY. PART NUMBER DESCRIPTION 2625130172 SEAL/SEAT BOOSTER PMP HP75 AB/SS 1205514772-1 GASKET/ORING HP75 PP 29020350072 IMPELLER 5" HP75 CPVC80 B016080026 BOOSTER PUMP ASSY 1PH HP75...
  • Page 170 B016080027 BOOSTER PUMP ASSY 3PH HP75 ITEM NO. QTY. PART NUMBER DESCRIPTION 1221514722-3 BRACKET,MTG,PUMP,BOOSTER 1205514772 BOOSTER PUMP HEAD HP75 W-4.75 IN IMPELLER 1520181110 MOTOR .50 HP 208-230-460-50-60 1920023632 STRAIN RELIEF 90 CG90-6250 0112653700 ADAP .75 MPT X.75 BARB NYLON 01120737DG ELB90 .75 MPT X .75 BARB NYLON 061172143016 SCREX,HEX A,.25x1.00,SS...
  • Page 171 RECOMMENDED SPARES: QTY. PART NUMBER DESCRIPTION 2625130172 SEAL/SEAT BOOSTER PMP HP75 AB/SS 1205514772-1 GASKET/ORING HP75 PP 29020350072 IMPELLER 5" HP75 CPVC80 B016080027 BOOSTER PUMP ASSY 3PH HP75...
  • Page 172: Media Filter Assy -4 Hs/Aw/Uw B071080002

    Aqua Matic Modular 450-1800 MEDIA FILTER ASSY -4 HS/AW/UW B071080002 PART NUMBER DESCRIPTION 0708040468-1 MEDIA FILTER HOUSING 818 ALMOND 20200404010 BRACKET ""L"" MOUNTING FEET 20200325000 SKID MEDIA FILTER AS>7/97 061100043000 WASHER FLAT OS 1/4"SS 061060045000 NUT HEX 1/4-20 W/INSERT SS 05180851CC GAUGE BRACKET CBM SS 0204010869...
  • Page 173 Aqua Matic Modular 450-1800 MEDIA SAND #A1000 25 POUNDS MEDIA GARNET 8-12 17 POUNDS Page 10-11...
  • Page 174: Multi Media Filter Plumbing Assy B075000001

    Aqua Matic Modular 450-1800 MULTI MEDIA FILTER PLUMBING ASSY B075000001 ITEM PART NUMBER DESCRIPTION 05180851CC GAUGE BRACKET CBM SS 0101693783 UNION .75 SL x .75 SL PVC 0101673783 UNION .75 FNPT x .75 FNPT PVC 14011317AR VALVE 3-WAY BALL .75 SL 0101652683 ADAP 1/2 MPT X 3/4 BARB PVC 0204020869...
  • Page 175: Plankton Filter Assy-Single B008800001

    Aqua Matic Modular 450-1800 PLANKTON FILTER ASSY-SINGLE B008800001 ITEM PART NUMBER DESCRIPTION B008800001 PLANKTON FILTER ASSY-AW SINGLE (INCLUDES P/N 2-7) 05181434AA HOSE CLAMP 3/4” SS 0805823578 ELEMENT PLANKTON 0101073783 ELB90 .75 MNPT X .75 BARB PVC 20200402102 SINGLE FILTER BRACKET 0713020473 FILTER HOUSING-LID .75 X 10 ASM 2614010473...
  • Page 176: Plankton Filter Assy-Double B008800002

    Aqua Matic Modular 450-1800 PLANKTON FILTER ASSY-DOUBLE B008800002 ITEM PART NUMBER DESCRIPTION 0713020473 FILTER HOUSING-LID .75 X 10 ASM 01013737CL NIPPLE .75 NPT X CLOSE PVC 0101423783 TEE .75 FNPT x .75 FNPT x .75 FNPT PVC 0101653783 ADAP 3/4 MPT X 3/4 BARB PVC 0101013783 ELB90 .75 FPT X .75 FPT PVC 0101073783...
  • Page 177 Oil/Water Separator Elements). Use only Sea Recovery supplied Prefiltration Elements. Third party prefiltration elements on the market do not properly fit into the Sea Recovery Filter Housings, the seams fall apart, and they will allow by-pass resulting in EXTENSIVE AND EXPENSIVE DAMAGE TO THE HIGH PRESSURE PUMP AS WELL AS PREMATURE FOULING OF THE R.O.
  • Page 178: Prefilter Dual Aqm Ii B108140001

    Aqua Matic Modular 450-1800 PREFILTER DUAL AQM II B108140001 ITEM NO. PART NUMBER DESCRIPTION QTY. B108140001 PREFILTER DUAL AQM II (INCLUDES P/N 2-8) 0801130257 ELEMENT PREFILTER 10-25 0801060157 ELEMENT PREFILTER 10-05 20200402101 DUAL BRACKET PREFILTER, CHRCL, PLNKTN 0112072600 ELB90 1/2 MPT X 3/4 BARB NYLON 05181434AA HOSE CLAMP 3/4"...
  • Page 179 Aqua Matic Modular 450-1800 Page 10-17...
  • Page 180: Commercial Prefilter Assy 32.5 Sq Ft Src Aqm B109120001

    Aqua Matic Modular 450-1800 COMMERCIAL PREFILTER ASSY 32.5 SQ FT SRC AQM B109120001 ITEM PART NUMBER DESCRIPTION B109120001 COMMERCIAL PREFILTER ASSY 32.5 SQ FT (INCLUDES P/N 2-11) 2614018969 O-RING 034 FOR COMMERCIAL FILTER 3901040100 ADAPTER SPACER RING 0204020100 ELB90 .25 TUBE JQ x .25MNPT 0204990300 PLUG 1/4 JQ 05181434AA...
  • Page 181: Oil / Water Separator Assy Src 32.5 Sq Ft B111120001

    Aqua Matic Modular 450-1800 OIL / WATER SEPARATOR ASSY SRC 32.5 SQ FT B111120001 ITEM PART NUMBER DESCRIPTION B111120001 OIL / WATER SEPERATOR ASSY SRC 32.5 SQ FT (INCLUDES P/N 2-9) 08020723KD ELEMENT OWSE 32.5 SQFT 0101653783 ADAP 3/4 MPT X 3/4 BARB PVC 05181434AA HOSE CLAMP 3/4"...
  • Page 182 B156140001 HP PUMP / MOTOR ASSY AQMCII APP ITEM NO. QTY. PART NO. DESCRIPTION B156140001 HP PUMP MOTOR ASSY 1 PHASE (INCLUDES P/N 2-24) 15AE261912 MOTOR 3/2.5 HP 115/230 1PH 12572405DS HPRA PUMP 4.37 GPM (CP) 1317021869 ELB90 -6 FLARE X 3/4 UNF SS 12207602RW COUPLER TX1 AQM2 061120091000...
  • Page 184 B156140002 HP PUMP / MOTOR ASSY AQMCII APP 3PH ITEM NO. QTY. PART NO. DESCRIPTION B156140002 HP PUMP / MOTOR ASSY AQMC II 3PH (INCLUDES P/N 2-24) 15AF271910 MOTOR 3/2.5 HP 3 PH AQM 50/6 12572405DS HPRA PUMP 4.37 GPM (CP) 1317021869 ELB90 -6 FLARE X 3/4 UNF SS 12207602RW...
  • Page 186 B156140003 HP PUMP/MOTOR ASSY AQMCII PLGR 110/220/5/6/1PH (Standard) ITEM NO. PART NO. DESCRIPTION B156140003 HP PUMP MOTOR ASSY AQMC II PLGR 110/220/5/6/1PH (INCLUDES P/N 2-21) 15AC062412 MOTOR 2.5 HP 50/60 110/220 061142157016 BOLT HEX 3/8-16 X 1 SS 061080056000 WASHER FLAT 3/8" SS 061142150016 BOLT HEX 5/16-18 X 1.0LG SS 061060050000...
  • Page 188 B156140004 HP PUMP/MOTOR ASSY AQMCII PLGR 220/440/60/3PH ITEM NO. PART NO. DESCRIPTION B156140004 HP PUMP MOTOR ASSY AQMC II PLGR 220/440/60/3PH (INCLUDES P/N 2-21) 061142157016 BOLT HEX 3/8-16 X 1 SS 061080056000 WASHER FLAT 3/8" SS 061142150016 BOLT HEX 5/16-18 X 1.0LG SS 061060050000 HEX NUT 5/16-18 W/INSERT SS 061100049000...
  • Page 190 B156140006 HP PUMP/MOTOR PLGR AQMCII 110/220/6/1 SMALL 60 ITEM NO. PART NO. DESCRIPTION B156140003 HP PUMP MOTOR PLGR AQMC II 110/220/6/1SMALL 60 HZ (INCLUDES P/N 2-21) 15AC062412 MOTOR 2.5 HP 50/60 110/220 061142157016 BOLT HEX 3/8-16 X 1 SS 061080056000 WASHER FLAT 3/8"...
  • Page 192 Aqua Matic Modular 450-1800 This page is intentionally left blank. Page 10-25...
  • Page 193: Hp Pump Assy-12180513Co (Standard)

    Aqua Matic Modular 450-1800 HP PUMP ASSY-12180513CO (Standard) ITEM NO. PART NUMBER DESCRIPTION 1-52 12180511CO Pump HP 3.0 GPM SS Left (complete high pressure pump) 12180512CO Pump HP 4.2 GPM SS Left (complete high pressure pump) 1-29 12180511CO-CCAL Crank Case Stuffed HP 3.0 GPM SS Left 12180512CO-CCAL Crank Case Stuffed HP 4.2 GPM SS Left 30-52...
  • Page 194 Aqua Matic Modular 450-1800 HP Pump Assy - Cont. ITEM NO. PART NUMBER DESCRIPTION 12180510CO-44 O-ring Valve Plug 12180510CO-46 Washer, Ribbed Lock 12180510CO-47 Screw SHCSM5 x 25mm Long 12180510CO-48 Screw SHCSM5 x 35mm Long 12180513CO-51 Valve Cap 12180510CO-52 Valve Assembly 2.3 through 4.2 GPM B647800003 Pump Oil 16oz REPAIR KITS:...
  • Page 195: Hp Hose Assembly

    Aqua Matic Modular 450-1800 HP HOSE ASSEMBLY PART NUMBER DESCRIPTION 2432160669 HOSE HP - 6P 1317481969 SWIVEL FITTING - 6 SSP Page 10-28...
  • Page 196: Membrane Rack 450-1 - B198000032

    Aqua Matic Modular 450-1800 MEMBRANE RACK 450-1 - B198000032 (cont.) ITEM NO. QTY. PART NUMBER DESCRIPTION 2408132500 VESSEL HIGH PRESSURE 450GPD ITEM NO. QTY. PART NUMBER DESCRIPTION 2724011233 MEMBRANE 450GPD W-SEAL 20201030000 SEGMENT RING AW (SET) 0520210600 RETAINER PORT MVA AW 2432160669 HOSE HP -6P 2632180426...
  • Page 197: Membrane Rack 700-1 - B198000033

    Aqua Matic Modular 450-1800 MEMBRANE RACK 700-1 - B198000033 ITEM NO. QTY. PART NUMBER DESCRIPTION 2408132500-01 VESSEL HIGH PRESSURE 700GPD 2724011333 MEMBRANE 700GPD W-SEAL 0520210600 RETAINER PORT MVA AW 2614014900 O-RING 230 BRINE 3" END PLUG 2614010100 O-RING 116 PRODUCT 0101370820 NIPPLE .25 NPT X 2.0 PVC 2453512400...
  • Page 198: Membrane Rack 900-1 - B198000034

    Aqua Matic Modular 450-1800 MEMBRANE RACK 900-1 - B198000034 ITEM NO. QTY. PART NUMBER DESCRIPTION 2408132500-02 VESSEL HIGH PRESSURE 900GPD 2724011433 MEMBRANE 900GPD W-SEAL 0520210600 RETAINER PORT MVA AW 2614014900 O-RING 230 BRINE 3" END PLUG 2614010100 O-RING 116 PRODUCT 0101370820 NIPPLE .25 NPT X 2.0 PVC 2453512400...
  • Page 199: Membrane Rack 900-2 - B198000035

    Aqua Matic Modular 450-1800 MEMBRANE RACK 900-2 - B198000035 (cont.) ITEM NO. QTY. PART NUMBER DESCRIPTION ITEM NO. QTY. PART NUMBER DESCRIPTION 2408132500 VESSEL HIGH PRESSURE 450GPD 20201030000 SEGMENT RING AW (SET) 2724011233 MEMBRANE 450GPD W-SEAL 2432160669 HOSE HP -6P 2632180526 DECOFELT .125 x 1.25 BLK 0520210600...
  • Page 200: Membrane Rack 1400-2 - B198000036

    Aqua Matic Modular 450-1800 MEMBRANE RACK 1400-2 - B198000036 (cont.) ITEM NO. QTY. PART NUMBER DESCRIPTION ITEM NO. QTY. PART NUMBER DESCRIPTION 2408132500 -01 VESSEL HIGH PRESSURE 700GPD 20201030000 SEGMENT RING AW (SET) 2724011333 MEMBRANE 700GPD W-SEAL 2632180526 DECOFELT 1/16 X 1 BLK ADH BACK 0520210600 RETAINER PORT MVA AW 2220010660...
  • Page 201: Membrane Rack 1800-2 - B198000037

    Aqua Matic Modular 450-1800 MEMBRANE RACK 1800-2 - B198000037 (cont.) ITEM NO. QTY. PART NUMBER DESCRIPTION ITEM NO. QTY. PART NUMBER DESCRIPTION 2408132500 -02 VESSEL HIGH PRESSURE 900GPD 20201030000 SEGMENT RING AW (SET) 2724011433 MEMBRANE 900GPD W-SEAL 2632180526 DECOFELT 1/16 X 1 BLK ADH BACK 0520210600 RETAINER PORT MVA AW 2220010660...
  • Page 202 Oil/Water Separator Elements). Use only Sea Recovery supplied Prefiltration Elements. Third party prefiltration elements on the market do not properly fit into the Sea Recovery Filter Housings, the seams fall apart, and they will allow by-pass resulting in EXTENSIVE AND EXPENSIVE DAMAGE TO THE HIGH PRESSURE PUMP AS WELL AS PREMATURE FOULING OF THE R.O.
  • Page 203: Controller Box A15M

    Aqua Matic Modular 450-1800 CONTROLLER BOX A15M ITEM NO. PART NUMBER DESCRIPTION QTY. B586150003 FRAME ASSY AQMM II B619940001 CONTROLLER CHASSIS 1 PH AQMMI B595160001 CONTROLLER AQM / AW DX NON CON B515150002 LP BACK PLATE ASSY B147130002 LP TRANSDUCER MANIFOLD ASSY AQWM/AQMM B476160003 BACK PRESS RGLR ASSY AQMMII Page 10-36...
  • Page 204: Controller Chassis 1 Ph B619940001

    Aqua Matic Modular 450-1800 CONTROLLER CHASSIS 1 PH B619940001 ITEM NO. PART NUMBER DESCRIPTION QTY. 3131232906 ELECTRICAL CHASSIS PLATE AQM/AQW MODULARS 31310603BF CONTACTOR 30A AW>12/99 12VDC 31318301DK EMI FILTER 3131380990 TERMINAL RING BLUE RB877 068162520005 SC PHIL PAN S/F 6-32 X 5/16 AL 31310110BF CONTACTOR 9A AUX AW>12/99 12VD 31311524DM...
  • Page 205: Controller Chassis 3 Ph B619940002

    Aqua Matic Modular 450-1800 CONTROLLER CHASSIS 3 PH B619940002 ITEM NO. PART NUMBER DESCRIPTION QTY. 3131232906 ELECTRICAL CHASSIS PLATE AQM/AQW MODULARS 31310603BF CONTACTOR 30A AW>12/99 12VDC 3131131500 TRANSFORMER 480/120 BUCK AQM 3131380990 TERMINAL RING BLUE RB877 068162520005 SC PHIL PAN S/F 6-32 X 5/16 AL 31310110BF CONTACTOR 9A AUX AW>12/99 12VD 31311524DM...
  • Page 206: Back Pressure Regulator Assy B476160003

    Aqua Matic Modular 450-1800 BACK PRESSURE REGULATOR ASSY B476160003 ITEM NO. PART NUMBER DESCRIPTION QTY. 2020043900 BRACKET MOUNT, BPR AQM II 1417017896 VALVE PRESS REGULATOR-AS B079400004 BPR GEAR ASSY AQM II 3421020100 COUPLER BACK PRESSURE REG-AQM 0204021769 ELB90 3/8 TUBE X 1/4 MPT PLASTIC 061222345006 SC ALLEN SET SCREW 1/4-20 x 3/8 LG 21010110MC...
  • Page 207: Lp Back Pressure Plate Assy B515150002

    Aqua Matic Modular 450-1800 LP BACK PRESSURE PLATE ASSY B515150002 (cont.) ITEM NO. PART NUMBER DESCRIPTION QTY. ITEM NO. PART NUMBER DESCRIPTION QTY. 0301094100 PIPE PVC SCH 80 3/8 0101191800 ELB90 3/8 SL X 3/8 FNPT PVC 11026920AO FLOWMETER IN-LINE .53 - 7.9 GPM 0103631700 ADAPT 3/8 MPT X 1/4 MPT SCH 40 3131680298...
  • Page 208: Lp Transducer Assy B147130002

    Aqua Matic Modular 450-1800 LP TRANSDUCER ASSY B147130002 ITEM NO. PART NUMBER DESCRIPTION QTY. 5301400600 MANIFOLD PRESSURE PICK UP AQM 0312121969 TUBE 1/4 BLACK 0204090869 CONN 1/4 TUBE X 1/4 MPT PLASTIC 2317100200 TRANSDUCER 0-200 PSI 7/16" SAE 061160631010 SC PHIL PAN #10-32 X 5/8 SS LP 3 (OPTIONAL) LP 2 LP 1...
  • Page 209: Ph Neutralizer / Charcoal Dual Aqmc Ii / Mod B114140001

    Aqua Matic Modular 450-1800 PH NEUTRALIZER / CHARCOAL DUAL AQMC II / MOD B114140001 ITEM NO. PART NUMBER DESCRIPTION QTY. B114140001 PH NEUTRALIZER / CHARCOAL DUAL AQMC II / MOD (INCLUDES P/N 2-9) 0713020573 FILTER HOUSING/LID 3/8 X 10 20200402101 DUAL BRACKET, PRE-FILTER, CHRCL/PLNKTN 08251950AS ELEMENT PH 9 3/4"...
  • Page 210: Clean And Rinse Kit Aqm B591120001

    Aqua Matic Modular 450-1800 CLEAN AND RINSE KIT AQM B591120001 ITEM PART NUMBER DESCRIPTION B591120001 CLEAN AND RINSE KIT AQM (INCLUDES P/N 2-6) 14011334AR VALVE 3-WAY BALL 3/4” MPT 0101063783 ELB90 3/4” FPT X 3/4” BARB PVC 0501164200 PIPE SUPPORT 1 1/8” #36 0101613783 ADAP 3/4 FPT X 3/4 BARB PVC 05181434AA...
  • Page 211: Fresh Water Flush (.50 Inch) B598000008

    Aqua Matic Modular 450-1800 FRESH WATER FLUSH (.50 INCH) B598000008 ITEM PART NUMBER DESCRIPTION 0713020873 FILTER HOUSING 1/2" X 10 EACH 0803004773 CHARCOAL FILTER 10 IN EACH 14172105AT VALVE CHECK .25 MNPT SS EACH 0204091769 CONN 3/8 TUBE X 1/4 MPT PLASTIC EACH 1401095998 VALVE SOLENOID 12VDC AED/CSFE...
  • Page 212 Aqua Matic Modular 450-1800 FRESH WATER FLUSH (.50 INCH) B598000008 - Illustration Page 10-45...
  • Page 213: Uv Sterilizer 12Vdc 2Gpm B5262000Cv

    Aqua Matic Modular 450-1800 UV STERILIZER 12VDC 2GPM B5262000CV Item No. Part No. Description 20010418002A Valve Bracket Clean/Rinse Kit 20010418001A Bracket Mount Saddle UV-AW Top 40000306CV UV Sterilizer 2 GPM 12VDC 40000100CV UV LAMP 2 GPM 2614019000 O-RING 212 QUARTZ SLEEVE 0204091869 CONN 3/8 TUBE X 3/8 MPT PLASTIC 0204021769...
  • Page 214: Remote Kit Display 80Ft Std Aqmii B610140008

    Aqua Matic Modular 450-1800 REMOTE KIT DISPLAY 80FT STD AQMII B610140008 ITEM PART NUMBER DESCRIPTION B610140008 REMOTE KIT DISPLAY 80FT STD AQMII (INCLUDES P/N 2-8) B612160001 REMOTE AQM II 31316802MT MICRO TEE MALE/FEMALE/FEMALE 31316806MT MICRO TERMINATION RESISTOR F 31316811MT MICRO DOUBLE-ENDED CORDSET 3M 31316806MT MICRO TERMINATION RESISTOR F 4900450008...
  • Page 215: Nmea 2000 Enabled B610140004

    Aqua Matic Modular 450-1800 NMEA 2000 ENABLED B610140004 ITEM NO. QTY. PART NUMBER DESCRIPTION 31316809MT MICRO CAP 31316801MT MICRO BULKHEAD FEED-THRU ASSY 31316812MT MICRO SINGLE ENDED CORDSET MALE Page 10-49...
  • Page 216 SOFT START ASSY B596800015 SOFT START 115V 50-60HZ B596800014 SOFT START 230V 50-60HZ...
  • Page 217: Foldout

    FOLDOUT PT-Pressure Transducer PI-Pressure Indicator M-Meter FG-Flow Gauge TDS-TDS Meter P-Pump PLC-Program Logic Controller Standard P&ID Sheet 11-1...
  • Page 218 PT-Pressure Transducer PI-Pressure Indicator M-Meter FG-Flow Gauge TDS-TDS Meter P-Pump PLC-Program Logic Controller Commercial P&ID Sheet 11-2...
  • Page 223 Part Number: B651140002 Sea Recovery Corporation P.O. Box 5288 • Carson, CA 90745-5288 • sales@searecovery.com www.searecovery.com...

Table of Contents