h. Once again, fill a 10-gallon container [53] with 10 gallons (38 liters) clean, fresh water.
i. Add to the 10 gallons of fresh water 1.5 lbs of Sea Recovery Membrane Cleaning Compound MCC 1, MCC 2 or
MCC 3. Thoroughly mix the solution until the cleaning compound has dissolved.
j. Configure the system for a Recirculating Closed Loop configuration as illustrated at the BOTTOM of pages 4
and 5 of this Section.
k. Start the System in the MANUAL MODE
8
Screen
9
th
th
055
Touch
Touch
BOOSTER PUMP
H P PUMP
l. Operate the System in the Recirculating Closed Loop configuration for 60 minutes. After 60 minutes stop the
system as follows:
10
Screen
11
th
057
Touch STOP
INFO
m. Configure the system for a Once Through Rinse configuration as illustrated at the TOP of pages 4 and 5 of this
Section.
n. Start the System in the MANUAL MODE to discharge the cleaning chemical to waste.
11
Screen
12
th
055
Touch
Touch
BOOSTER PUMP
H P PUMP
o. Operation of the System will deplete the cleaning solution in the bucket [53]. Just prior to depleting the
solution in the Bucket [53] stop the System.
13
Screen
14
th
057
Touch STOP
Screen
10
th
056
WARNING:
DO NOT INCREASE PRESSURE
Screen
th
055
Screen
13
th
th
056
WARNING:
DO NOT INCREASE PRESSURE
Screen
Info
th
055
section 6 page 15 of 18
Screen
057
Screen
057
Aqua Matic 450-1800 Rev. A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents