Optional Vacuum/Pressure Gauges may be added before and after each component in the feed
water line to give the operator accurate differential pressure across each component. This
simplifies diagnosis of feed water line abnormalities and allows the operator to pin-point which
component is in need of service. Order Part Number: B148000001, Description:
DIFFERENTIAL LOW PRES GAUGE ASSY

13. REVERSE OSMOSIS MEMBRANE ELEMENT NOTE:

CAUTION: Some systems are shipped WITHOUT the Reverse Osmosis Membrane Element. This is to
accommodate, for example, Boat Builders that install the system well in advance of commissioning the boat and
the Aqua Matic.
DOES THIS Sea Recovery Aqua Matic System HAVE R.O. MEMBRANE(S) INSTALLED OR NOT?
If not, is it your intention to install the R.O. Membrane(s) at this time, or do you wish to install them at a later
date when the boat is commissioned?
If the Reverse Osmosis Membrane Element has been installed, there will be a Reverse Osmosis Membrane
Element Serial Number tag, illustrated below, attached to the High Pressure Vessel(s). Find this Serial Number
tag to ensure that the R.O. Membrane Element(s) has been installed.
If the R.O. Membrane Element Serial
Number tag is missing or does not contain
a serial number and date then the R.O.
Membrane(s) is (are) not installed. If the
R.O. Membrane Element(s) is (are) are
not installed and you wish to install them
at this time contact Sea Recovery and
supply us with your original Purchase
Order Number, Sea Recovery's Invoice
Number, and this Aqua Matic's Serial
Number.
WARNING: IF THE REVERSE OSMOSIS MEMBRANE ELEMENT IS NOT TO BE
INSTALLED AT THIS TIME ENSURE THAT YOU LEAVE A VISIBLE NOTE AT
THE SYSTEM CONTROLLER AND AT THE FRONT OF THE CONTROL PANEL
INFORMING THE END USER THAT: THE REVERSE OSMOSIS MEMBRANE
ELEMENT(S) IS/ARE NOT INSTALLED; TO CONTACT THE FACTORY FOR THE
R.O. MEMBRANE ELEMENT(S); AND DO NOT OPERATE THE SYSTEM
WITHOUT THE R.O. MEMBRANE ELEMENT(S) INSTALLED.
EXTENSIVE DAMAGE WILL OCCUR IF THE AQUA TOUCH SYSTEM IS OPERATED
WITHOUT THE R.O. MEMBRANE ELEMENT(S) INSTALLED. DAMAGE TO
THE SYSTEM CAUSED BY THE OPERATION OF THE SYSTEM WITHOUT R.O.
MEMBRANE ELEMENT(S) INSTALLED IS: NOT COVERED BY THE SEA
RECOVERY WARRANTY; IS THE LIABILITY OF THE INSTALLER IF THE
INSTALLER DID NOT NOTIFY THE END USER; OR IS THE LIABILITY OF
THE END USER IF THE INSTALLER NOTIFIED THE END USER THAT THE
R.O. MEMBRANE(S) WERE NOT INSTALLED AND TO NOT OPERATE THE
SYSTEM WITHOUT THE R.O. MEMBRANE ELEMENT(S) INSTALLED.
Sea Recovery
Rancho Dominguez, California 90220 U.S.A.
Tel: 1-310-637-3400 ¦ Fax: 1-310-637-3430
Email: srcsales@searecovery.com
SERIAL NO:
--›
FLOW:
DATE:
section 2 page 25 of 56
Aqua Matic 450-1800 Rev. A
Inline Vacuum /
Pressure Gauge
087945021505
BRINE INLET END
October 15, 2005