No.
Name
CP.18
ANOUT 1 gain
0...±20.00
No.
Name
CP.19
Comparison level 0
This parameter determines the switching level for transistor output O1, as well as relay
output 2.
Setting range
0...3200.00 V
No.
Name
CP.20
General fault reset
Setting range
0
1...10
No.
Name
CP.21
Last error
CP.22
Last error -1
CP.23
Last error -2
CP.24
Last error -3
CP.25
Last error -4
CP.26
Last error -5
CP.27
Last error -6
CP.28
Last error -7
Parameters CP.21...CP.28 display the last eight errors. With exception error "Underpotential
E.UP" is not stored. The oldest error is displayed in CP.28. A new error is stored in CP.21.
All other errors are shifted to the next parameter. The oldest error (CP.28) is not applicable.
The meaning of the error messages is described in parameter CP.01.
The amplification to the desired output voltage can be
1.00
adapted with CP.18. Max. possible: ±10 V.
Setting
Meaning
The switching condition is fulfilled and the transistor
output is set if the DC voltage level exceeds the ad-
600.00 V
justed value in CP.19. Relay output 2 is set, if the load
shunt relay is additionally tightened.
A general fault reset can be activated with this parameter. Atten-
tion, the machine manufacturer must observe appropriate protective
measures for operating personnel and machine.
Setting
Meaning
No general fault reset.
Maximum errors, which are reset within one hour. If the
3
number of errors per hour exceeds the adjusted value
in CP.20, only a manual reset via the terminal strip can
be made.
Special adjustments
r/w
Enter
yes
–
r/w
Enter
yes
–
r/w
Enter
yes
–
r/w
Enter
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
based on
An.33
based on
LE.00
based on
Pn.15
based on
In.24 set 0
In.24 set 1
In.24 set 2
In.24 set 3
In.24 set 4
In.24 set 5
In.24 set 6
In.24 set 7
GB - 45