Rs-232C Protocol - Kyocera FS-2000D Advanced Operation Manual

Kyocera fs-2000d: advanced operation
Hide thumbs Also See for FS-2000D:
Table of Contents

Advertisement

RS-232C Protocol

Parameters of the RS-232C Protocol
ADVANCED OPERATION GUIDE
A protocol is a set of rules followed by various devices to send or receive
data. The parameters of the RS-232C protocol are stored in the battery-
powered memory of the printer. You can verify these parameters on the
status printout as marked by the following identifications:
H1: Baud rate
H2: Number of data bits
H3: Number of stop bits
H4: Parity
H5: Protocol logic
H6: Buffer-nearly-full threshold
H7: Buffer nearly-empty threshold
H8: Received data buffer size
The parameters can be changed from the printer operation panel. To
change the value for the serial interface parameters, refer to Changing
Serial Interface Parameters on page 2-31.
This following section outlines the parameters and their values you can
select on the operation panel:
H1: Baud rate
Parameter value
12
24
48
96
19
38
57
11
The factory setting is 96 (9600 baud).
H2: Number of data bits
7 or 8. The factory setting is 8.
H3: Number of stop bits
1 or 2. The factory setting is 1.
Baud rate
1200
2400
4800
9600
19200
38400
57600
115200
Computer Interface