6.17 Options for Meter Menu (8)
Abbreviation
Variable Name
%ESP
Encoder Speed
ERPM
Encoder Speed
IAF
Phase A filter current
IBF
Phase B filter current
ICF
Phase C filter current
MVAO
Measured Phase A volts
MVBO
Measured Phase B volts
MVCO
Measured Phase C volts
MVNG
Measured Output Neutral Voltage
%MAV
Max Avail Output Volts
KVAR
Input Avg Reactive Power
LOSS
Excessive Drive Losses
XRCA
Excessive Reactive current
UXFR
Up Transfer State value
DXFR
Down Transfer State value
%DRP
Speed Droop
Figure 6-8
Standard Keypad Dynamic Programmable Meter Display
Figure 6-9
164
Units
%
rpm
A
A
A
V
V
V
V
%
KVAR
kW
A
%
Multi-Language Keypad Dynamic Programmable Meter Display
Description
Motor encoder speed.
Motor encoder speed.
Output Filter Current Ia.
Output Filter Current Ib.
Output Filter Current Ic.
Voltage Phase A (Va) at drive output.
Voltage Phase B (Vb) at drive output.
Voltage Phase C (Vc) at drive output.
Output drive neutral voltage.
Output maximum available output voltage.
Input drive average reactive power.
Drive internal power losses (input - output).
Input reactive current over max allowed.
Up transfer state machine state variable.
Down transfer state machine state variable.
Motor speed droop. Speed slow-down proportional to tor‐
que current.
NXGPro+ Control Manual