8.2 DEFINED CONTENTS OF AUXILIARY OUTPUT PORTS 1-10

8.2.1

DEFINED CONTENTS TABLE OF AUXILIARY OUTPUT PORTS 1-10

Table 11 Defined Contents Table of Auxiliary Output Ports 1-10
No.
Type
0
Not Used
1
Custom Period 1
Custom Period 2
2
Custom Period 3
3
4
Custom Period 4
Custom Period 5
5
6
Custom Period 6
7
Custom Combined 1
Custom Combined 2
8
Custom Combined 3
9
10
Custom Combined 4
Custom Combined 5
11
12
Custom Combined 6
13
Reserved
14
Reserved
15
Air Flap Control
16
Audible Alarm
17
Louver Control
18
Fuel Pump Control
19
Heater Control
20
Cooler Control
21
Fuel Pre-supply
22
Screw Oil Cooler Control 1
ACC7200 Air Compressor Controller User Manual
Function Description
Please refer to the following contents for function details.
Act at the time of over speed shutdown alarm and emergency
stop; Air flap can be closed to realize fast stop.
Act at the time of warning and shutdown alarms; Announciator
can be connected externally; It can be inhibited to output when
input port "Alarm Mute" is active or any button is pressed; When
there is new warning or shutdown alarm, it outputs again.
Act at the time of engine start; Disconnect after engine stop.
Act by fuel level sensor of fuel pump controlling the upper and
lower limits;
Act by temp. sensor of heater control controlling the upper and
lower limits;
Act by temp. sensor of cooler control controlling the upper and
lower limits;
Under standby state, fuel pre-supply output port is active and it
outputs circularly according to pre-set "Fuel Pre-supply Rest
Time" and "Fuel Pre-supply Time"; If "Fuel Pre-supply Rest Time"
is 0h, then it doesn't output;
Before start, pre-set pre-supply time is outputted; If pre-heat time
is not configured, pre-supply outputs; If pre-heat time is
configured, then pre-heat phase outputs;
When the external discharge temperature sensor value is higher
than the open value, cooler will output; when it is lower than the
close value, cooler not output.
When the max. open time set as 0, output port works according
to the open and close values, not limited by the max. open time.
Page 48 of 77